Interlogix ZEROWIRE ZW-6404 Installation Manual page 94

Wireless security & home automation
Table of Contents

Advertisement

Zone Doubling can only be used with Normally Closed devices.
End Of Line Resistors for Non-Zone Double (2 inputs):
ANY INPUT
GROUND
TERMINAL
TERMINAL
3.3K
E.O.L.
N.C. CONTACT
WITH EOL RESISTOR
End Of Line Resistors for Zone Double (4 inputs):
Resistor Diagram:
94
ANY INPUT
GROUND
TERMINAL
TERMINAL
3.3K
E.O.L.
N.O. CONTACT
WITH EOL RESISTOR
ANY INPUT
GROUND
TERMINAL
TERMINAL
6.98K
E.O.L. (3 - 4)
3.74K
E.O.L. (1 - 2)
3.74K RESISTOR FOR
ZONES 1 - 2
6.98K RESISTOR FOR
ZONES 3 - 4
ZONE DOUBLE E.O.L.
SINGLE ZONE E.O.L.
ZONES 1 - 2
BROWN
GOLD
BROWN
3.3K
RED
YELLOW
Ohm
ORANGE
VIOLET
ORANGE
ORANGE
ANY ZONE
ANY INPUT
GROUND
TERMINAL
TERMINAL
TERMINAL
3.3K
E.O.L.
ONE N.O. CONTACT &
ONE N.C. CONTACT
WITH EOL RESISTOR
ANY INPUT
ANY GROUND
TERMINAL
TERMINAL
3.74K
E.O.L.
ZONE DOUBLED
CONFIGURATION USED
AS A FIRE ZONE,
UPPER ZONE (3 - 4)
IS NOT USEABLE
ZONE DOUBLE E.O.L.
ZONES 3 - 4
BROWN
BROWN
6.98K
3.74K
GRAY
Ohm
Ohm
WHITE
BLUE
ANY COM
TERMINAL
TAMPER
CONTACT
3.3K
E.O.L.
ZONE TAMPER
EOL RESISTOR

Hide quick links: