Connecting Inputs
ZeroWire has two general purpose inputs located on the rear of the unit. These can be
connected to up to 4 devices when Zone Doubling is enabled. Use the supplied header
cable.
To disable the inputs:
•
Set System Menu -> General Options -> Disable Hardwired Zones = ON
To enable 2 inputs:
•
Set System Menu -> General Options -> Disable Hardwire zones = OFF
•
Set System Menu -> General Options -> Panel Zone Doubling = OFF
•
Set System Menu -> General Options -> Double EOL = ON for tamper monitoring,
To enable 4 inputs without tamper monitoring:
•
Set System Menu -> General Options -> Disable Hardwire Zones = OFF
•
Set System Menu -> General Options -> Panel Zone Doubling = ON
•
Set System Menu -> General Options -> Double EOL = OFF
IMPORTANT NOTES:
•
If hard wired inputs are programmed as zone 1, 2, 3, and/or 4, then these will take
priority over the wireless detectors.
•
System Double EOL will take priority over Zone EOL setting. If Zone EOL is OFF and
Double EOL is on, Double EOL tamper monitoring will be active.
•
Normally Open or Normally Closed state can be set in Zone Options -> Options.
ZeroWire Installation Manual
Input/Output
Input/Output
Pin Outs
Pins
Connector
Connector
1. Ground
1. Ground
2. Input 1
2. Input 1
3. Input 2
3. Input 2
4. Output 1
4. Output 1
5. Output 2
5. Output 2
6. 8.5V+
6. 8.5 V+
or OFF for no tamper
93