Connecting Inputs - Interlogix ZEROWIRE ZW-6404 Installation Manual

Wireless security & home automation
Table of Contents

Advertisement

Connecting Inputs

ZeroWire has two general purpose inputs located on the rear of the unit. These can be
connected to up to 4 devices when Zone Doubling is enabled. Use the supplied header
cable.
To disable the inputs:
Set System Menu -> General Options -> Disable Hardwired Zones = ON
To enable 2 inputs:
Set System Menu -> General Options -> Disable Hardwire zones = OFF
Set System Menu -> General Options -> Panel Zone Doubling = OFF
Set System Menu -> General Options -> Double EOL = ON for tamper monitoring,
To enable 4 inputs without tamper monitoring:
Set System Menu -> General Options -> Disable Hardwire Zones = OFF
Set System Menu -> General Options -> Panel Zone Doubling = ON
Set System Menu -> General Options -> Double EOL = OFF
IMPORTANT NOTES:
If hard wired inputs are programmed as zone 1, 2, 3, and/or 4, then these will take
priority over the wireless detectors.
System Double EOL will take priority over Zone EOL setting. If Zone EOL is OFF and
Double EOL is on, Double EOL tamper monitoring will be active.
Normally Open or Normally Closed state can be set in Zone Options -> Options.
ZeroWire Installation Manual
Input/Output
Input/Output
Pin Outs
Pins
Connector
Connector
1. Ground
1. Ground
2. Input 1
2. Input 1
3. Input 2
3. Input 2
4. Output 1
4. Output 1
5. Output 2
5. Output 2
6. 8.5V+
6. 8.5 V+
or OFF for no tamper