8.
Repeat this procedure from Step 6 until all your pumps pulse rates are defined. The system
displays: NO. OF TANKS: <1-8>
9.
Type the number of tanks in your configuration and press RETURN. The system displays:
SYSTEM ID: <xxxx>
10. Type the unique number for your system and press RETURN. The system displays:
PRICE DATA FORMAT
0 = NO PRICE DATA
1 = UNIT PRICE
2 = UNIT & TOTAL PRICE
ENTER FORMAT: <0,1,2>
11. Type a number from 0 to 2 and press RETURN to set a price data format for your pumps and
transactions. The system displays:
AUTO PUMP DISABLE
NO. OF ZERO QTY. TRANS. <1-99>
12. Type the number of consecutive zero quantity transactions to trigger automatic pump disable
and press RETURN. Usual values are 3 or 5. The system displays:
LINES PER PAGE: <0-62>
13. Type the number of lines to print on each page.
combination, type 62, otherwise, type zero.
The system displays:
CARD EXPIRATION DATE
ENABLE OR DISABLE <E OR D>
14. To disable the card expiration date feature, type D and press RETURN. The system accepts
all dated cards as valid regardless of their expiration date.
To enable the card expiration date feature, type E and press RETURN. The system checks
expiration dates and denies access to those cards with past dates.
The system displays:
AUTO PIN LOCKOUT
ENABLE OR DISABLE <E OR D>
15. To enable automatic PIN lockout (card locked out after three unsuccessful PIN entries), type
E and press RETURN.
To disable automatic PIN lockout, type D and press RETURN.
The system displays:
AUTO SITE SHUT DOWN
ENABLE OR DISABLE <E OR D>
05/29/03
System Maintenance Commands
If you are using a terminal/printer
5-5