Mitsubishi FX3U-232-BD User Manual page 429

Fx3u series
Hide thumbs Also See for FX3U-232-BD:
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
FREQROL F700 Series
Pr
Function
No.
244
Cooling fan operation selection
245
Rated slip
Slip
246
Slip compensation time constant
compensation
Constant-power region slip
247
compensation selection
250
Stop selection
Output phase failure protection
251
selection
Frequency
252
Override bias
compensation
253
Override gain
function
255
Life alarm status display
Inrush current limit circuit life
256
display
Control
Life check
257
display
258
Main circuit capacitor life display
Main
circuit
259
measuring
PWM
260
switchover
261
Power failure stop selection
Subtracted frequency at
262
deceleration start
263
Subtraction starting frequency
Power failure
Power−failure deceleration time
264
stop
1
Power−failure deceleration time
265
2
Power failure deceleration time
266
switchover frequency
267
Terminal 4 input selection
268
Monitor decimal digits selection
Load torque
high speed
frequency
control
Name
Pr No.
244
245
246
247
250
251
252
253
255
256
circuit
capacitor
life
257
258
capacitor
life
259
frequency
automatic
261
262
263
264
265
266
267
268
270
271
272
273
274
FREQROL A700 Series
Name
Cooling fan operation selection
Rated slip
Slip compensation time constant
Constant-power region slip
compensation selection
Stop selection
Output phase failure protection
selection
Override bias
Override gain
Life alarm status display
Inrush current limit circuit life
display
Control
circuit
capacitor
life
display
Main circuit capacitor life display
Main
circuit
capacitor
life
measuring
Power failure stop selection
Subtracted frequency at
deceleration start
Subtraction starting frequency
Power-failure deceleration time 1
Power-failure deceleration time 2
Power failure deceleration time
switchover frequency
Terminal 4 input selection
Monitor decimal digits selection
Stop-on contact/load torque high
speed frequency control
selection
High-speed setting maximum
current
Middle-speed setting minimum
current
Current averaging range
Current
averaging
filter
time
constant
12 Related Data
12.5 FREQROL Inverter Parameter List
FREQROL E700 Series
Pr
Name
No.
244
Cooling fan operation selection
245
Rated slip
246
Slip compensation time constant
Constant-power region slip
247
compensation selection
Earth (ground) fault detection at
249
start
250
Stop selection
Output phase loss protection
251
selection
255
Life alarm status display
Inrush current limit circuit life
256
display
Control
circuit
capacitor
257
display
258
Main circuit capacitor life display
Main
circuit
capacitor
259
measuring
261
Power failure stop selection
267
Terminal 4 input selection
268
Monitor decimal digits selection
270
Stop-on contact control selection
E-139
A
B
C
D
life
life
E
F
G
H
I
Apx.

Advertisement

Table of Contents
loading

Table of Contents