JY997D26301A
FX
-485ADP-MB
3U
Installation Manual
Manual Number
JY997D26301
Revision
A
Date
April 2007
This manual describes the part names, dimensions, mounting, and
specifications of the product. Before use, read this manual and manuals of
relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
®
MODBUS
is a registered trademark of Schneider Electric S.A.
The company name and the product name to be described in this manual are
the registered trademarks or trademarks of each company.
Effective April 2007
Specifications are subject to change without notice.
©
2007 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
This manual classify the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on circumstances, procedures indicated by
linked to serious results.
In any case, it is important to follow the directions for usage.
Associated Manuals
Manual name
Manual No.
Description
Explains FX
3U
FX
Series
JY997D16501
3U
specification details for I/O,
User's Manual
MODEL CODE:
w i r i n g , i n s t a l l a t i o n , a n d
- Hardware Edition
09R516
maintenance.
FX
/FX
Series
3U
3UC
JY997D16601
Describes PLC programming
Programming Manual
MODEL CODE:
for basic/applied instructions
- Basic & Applied
and devices.
09R517
Instruction Edition
FX Series User's
Explains N:N link, parallel
JY997D16901
Manual
link, computer link, no
MODEL CODE:
- Data Communication
protocol communication by
09R715
RS instructions/FX
Edition
FX
3U
Series User's
Manual
Explains the MODBUS serial
JY997D26201
- MODBUS Serial
communication network.
Communication Edition
How to obtain manuals
For the necessary product manuals or documents, consult with the Mitsubishi
Electric dealer from where you purchase your product.
Certification of UL, cUL standards
The FX
3U
-485ADP-MB unit supports UL and cUL standards.
UL, cUL file number :E95239
Compliance with EC directive(CE Marking )
This document does not guarantee that a mechanical system including this product will
comply with the following standards.
Compliance to EMC directive of the entire mechanical system should be checked by
the user / manufacturer. For more details please contact the local Mitsubishi Electric
sales site.
Requirement for Compliance with EMC directive
The FX
-485ADP-MB is compliant through direct testing (of the identified standards
3U
below) and design analysis (through the creation of a technical construction file) to the
European Directive for Electromagnetic Compatibility (89/336/EEC) when used as
directed by the appropriate documentation.
Standard
EN61131-2:2003
Compliance with all relevant aspects of the
Programmable controllers
standard.
- Equipment requirements and
• Radiated Emissions
tests
• Mains Terminal Voltage Emissions
• RF immunity
• Fast Transients
• ESD
• Voltage drops and interruptions
• Conducted
• Power magnetic fields
Caution for compliance with EC Directive
Installation in Enclosure
Programmable logic controllers are open-type devices that must be installed and used
within conductive control boxes. Please use the FX
controllers while installed in conductive shielded control boxes. Please secure the
control box lid to the control box (for conduction). Installation within a control box
greatly affects the safety of the system and aids in shielding noise from the
programmable logic controller.
1. Outline
The FX
-485ADP-MB communication special adapter (hereinafter called 485ADP-
3U
MB) is a special adapter for RS-485 communication with a terminal block (European
may also be
type).
485ADP-MB is an isolated signal exchange unit of RS-485 serial data communication
between the PLC and RS-485 device.
The FX
3U
-485ADP-MB features all functionality that is available with the FX
485ADP, except that it also has MODBUS communication available.
1.1 Communication Function
Series PLC
Communication type
Data transfer between up to eight FX Series PLCs by the
N:N network
simple program.
Data transfer between two FX Series PLCs specifying
Parallel link
master/slave station.
Data transfer via dedicated protocol between PLC and
Computer link
computer (specified as the master station).
Non-protocol
Serial communication via non-protocol between PLC and
communication
RS-485 device.
-232IF.
2N
Inverter
Controlling Mitsubishi's FREQROL inverter using inverter
communication
communication instruction.
MODBUS
Data transfer for up to 16 slaves controlled by one master.
communication
1.2 Incorporated Items
Check if the following product and items are included in the package:
Product
FX
-485ADP
3U
-MB
POWER
RD
SD
The label should be applied on the front of 485ADP-MB for checking station numbers
in N:N network, computer link, MODBUS Communication, etc.
Remark
1.3 External Dimensions, Part Names and Terminal Layout
[3]
[2]
• Surge
[1]
Series programmable logic
3U
7(0.28")
74(2.92")
Special adapter
connector cover
is removed
[1] DIN rail mounting groove (DIN rail: DIN46277)
[2] Name plate
[3] Special adapter slide lock:
3U
-
Used to connect special adapter on left side of this special adapter.
[4] Special adapter connector cover:
Remove this cover for connecting special adapter on the left side.
[5] Direct mounting hole:2 holes of φ4.5 (0.18") (mounting screw: M4 screw)
Function
[6] POWER LED (green): Lit while 5V DC power is supplied from main unit.
[7] RD LED (red):
Lit while receiving data from connected RS-485 device.
[8] SD LED (red):
Lit while sending data to connected RS-485 device.
[9] Terminal resistor selector switch (330Ω/OPEN/110Ω)
[10] Special adapter connector:
Used to connect this special adapter to PLC main unit or special adapter.
[11] Terminal block (European type) for connecting RS-485 device
Use to connect RS-485 device to 485ADP-MB.
[12] DIN rail mounting hook
[13] Special adapter fixing hook
[14] Special adapter connector:
Used to connect communication special adapter or analog special adapter to
this adapter on left side.
1.4 Terminal Configuration
The terminal configuration of the RS-485 terminal on the 485ADP-MB is shown
below.
Manual
Label
Terminal screws
リンク用局番ラベル
Netwrork Station No.
JY818D61301A
Sta tion 0
Sta tion 1
This
Sta tion 2
Sta tion 3
manual
Sta tion 4
Sta tion 5
Sta tion 6
Sta tion 7
Sta tion 8
Sta tion 9
Sta tion 10
Sta tion 11
Sta tion 12
Sta tion 13
Sta tion 14
Sta tion 15
Sta tion 16
Station
Station
1.5 Terminal Resistor Selector Switch
485ADP-MB has a built-in terminal resistor.
A terminal resistor may be required depending on the communication type. Refer to
[13]
the following manual for the terminal resistor setting.
[4]
[5]
→ Refer to FX Series User's Manual - Data Communication Edition, and FX
[6]
FX
-485ADP
3U
-MB
[7]
[8]
330Ω
RDA
[9]
OPEN
RDB
[10]
SDA
110Ω
SDB
[11]
SG
2. Channel Allocation
Up to two communication ports can be added to the main unit.
Communication
communication special adapter to the main unit is ch1.
• Using one communication special adapter + communication expansion board
15.1
15.5
[12]
(0.6")
(0.65")
17.6
[14]
(0.7")
function
Weight: Approx. 80g (0.18 lbs)
adapter
• Using two communication special adapters
function
adapter
Signal direction
Signal
Function
RS-485
name
485ADP-MB
equipment
RDA(RXD+)
Receive data
←
RDB(RXD-)
SDA(TXD+)
Send data
→
SDB(TXD-)
−
SG(GND)
Signal ground
Series User's Manual - MODBUS Serial Communication Edition.
Setting terminal
Setting no
Setting terminal
resistor to 330Ω
terminal resistor
resistor to 110Ω
330Ω
330Ω
OPEN
OPEN
110Ω
110Ω
port
channels
are
automatically
allocated.
The
closer
Communication function
(ch2)
extension board (ch1)
Analog
Analog
FX
-
Analog
Analog
3U
special
special
485ADP
special
special
Main unit
function
-MB
function
function
adapter
adapter
adapter
(ch2)
(ch1)
FX
-CNV-BD
3U
Analog
Analog
FX
-
Analog
Analog
FX
-
3U
3U
special
special
485ADP
special
special
485ADP
Main unit
function
-MB
function
function
-MB
adapter
adapter
adapter
3U
Need help?
Do you have a question about the MELSEC-F FX3U and is the answer not in the manual?
Questions and answers