JY992D51301C
This manual contains text,diagrams and explanations which will guide the reader in the correct installation and operation
of the FX
-232ADP and should be read and understood before attempting to install or use the unit.
0N
Further information can be found in the FX SERIES PROGRAMMING MANUAL and FX
/FX
HARDWARE MANUAL.
0
0N

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi FX0N-232ADP

  • Page 1 -232ADP COMMUNICATION ADAPTER USER'S GUIDE JY992D51301C This manual contains text,diagrams and explanations which will guide the reader in the correct installation and operation of the FX -232ADP and should be read and understood before attempting to install or use the unit. Further information can be found in the FX SERIES PROGRAMMING MANUAL and FX HARDWARE MANUAL.
  • Page 2: Rs232C Device

    The FX -232ADP type RS232C adapter (hereinafter called 232ADP) is connected to the FX series PC to exchange serial data with a personal computer, barcode reader, printer, and other various RS232C devices. Only one 232ADP unit can be connected to one base unit to the serial port provided at the left side.
  • Page 3: Performance Specification

    INSTALLATION NOTES AND USAGE Performance specification Transmission standard Conforming to RS232C, 25pin D-SUB, connector used Isolation method Photo coupler isolation Transmission distance 15m or less (shielded cable recommended) Current consumption DC 5V less than 200mA from base unit M8121:Send wait flag M8122:Send flag Control flags and M8123:Receive completion...
  • Page 4 For data transmission to be effective it is necessary to match the communication format between the product and the RS232C device, such as Baud rate and parity. Communication format D8120 (bit mapping) Description 0(OFF) Data length 7bit Parity Stop 1bit Baud rate (bps) The communication format is set by special data register D8120.
  • Page 5: Connection Examples

    The connections of RS232C devices varies with each device being used. Check the specification of the device, and connect. Connection examples Terminal specification device When RS232C device uses pins 6,20 232ADP RS232C RS232C device device WIRING Modem specification device When RS232C device uses pins 4,5 232ADP RS232C...
  • Page 6: Program Examples

    Connecting 232ADP and a printer,and printing out the data sent from the PC. Printer Send • Receive data The communication format of the serial printer is as follows. Data length 8 bit Parity Even Stop bit 2 bit Baud rate 2400bps Sequence program Operation...
  • Page 7 Connect 232ADP and a personal computer,and exchange data with the PC. Personal computer Send Receive • Send data • Receive data Use the communication cable suited to the connector pin configuration of the personal computer. (For representative wiring see section 4.) Preparation of software series sequencer The communication format of the PC for this example...
  • Page 8 Sequence program Operation Turn on the power of the PC and printer, check the printer is on Power on line and switch the PC to RUN. X000,ON RS instruction Turn on X000, and drive RS instruction. drive X001,ON Every time X001 is turned on, the contents of D200 to D210 are Data send sent to the personal computer, and "test data"...
  • Page 9 If data transfer does not perform correctly when using the 232ADP, check the operation using the following programs. Program when sending Set the communication format according to the external device to be used. Send request * Write the data to be sent to D 0 to D 19 before operating. DIAGNOSTICS If sending and receiving using these programs is successful, it is considered that the operation failure...
  • Page 10 Start • Check connection with the PC. Is power • Check power source of PC. LED lit? Is M8063 turned on? Send, receive error No send or receive error Only receiving fails to operate normally • Check wiring of control line. Is send •...
  • Page 11 • Check wiring of RS232C cable. • Make sure wiring of control line is suited to the external device. Is RD LED (receive) lit? • Make sure the external sending device is normal. • Check the voltage level of RS232C signal. Is M8123 turned on? No receive...
  • Page 12 Guidelines for the safety of the user and protection of the FX • This manual has been written to be used by trained and competent personnel. This is defined by the European directives for machinery, low voltage and EMC. • If in doubt at any stage during the installation of the FX engineer who is qualified and trained to the local and national standards.If in doubt about the operation or use of the FX -232ADP please consult the nearest Mitsubishi Electric distributor.