IAI SP-20000C-USB User Manual page 84

20 mp cmos digital progressive scan monochrome and color camera spark series
Table of Contents

Advertisement

Acquisition Start
1st
[Frame Start]
– [Trigger Source] Input
[Acquisition Transfer Start]
– [Trigger Source] Input
[Exposure Active] out
[Internal FVAL] out
1st
[Internal DATA] out
Frame Memory 1
"Hold"
Frame Memory 2
Frame Memory 3
Frame Memory 4
Data Stream Packet out
Example 3. How 4 memories can store image again
(1) Apply " [Frame Start Trigger]-[Trigger Source] Trigger signal" four times.
(2) Apply "[Acqusition Transfer Start]-[Trigger Source] signal once. By doing this input, the first stored image can be readout. And the memory which stores the first image becomes
available to store a new image.
(3) Apply "[Frame Start Trigger]-[Trigger Source] Trigger signal" once (This is fifth trigger signal). Then the image can be stored in memory.
(4) Apply "[Acqusition Transfer Start]-[Trigger Source] signal" twice. Those two signals clear the next two memories.
SP-20000M-USB / SP-20000C-USB
2nd
3rd
4th
3rd
4th
2nd
"Hold"
"Hold"
"Hold"
Fig. 38
- 82 -
5th
2nd
1st
5th
"Hold"
1st
2nd
"Output"
"Output"
Example 3
3rd
4th
5th
5th
3rd
4th
"Output"
"Output"
"Output"