Table – 38 (Cont) Minimum trigger interval calculation formula (Trigger Overlap = Readout)
Camera Settings
Pixel
Format
10 Bit_Packed
Monochrome
/
10 Bit_Packed
Bayer
12 Bit_Packed
Monochrome
/
12 Bit_Packed
Bayer
SP-20000M-USB / SP-20000C-USB
[Unit:us]
Binning
Vertical
1 (Off)
IF
(1/ [Trigger Overlap=Off Read Rate]) + 16.025us + 10us - 260us
≧ [Trigger Pulse Width]
= (1/[Trigger Overlap=Off Read Rate]) + 16.025us + 10us
IF
(1/ [Trigger Overlap=Off Readout Rate]) +16.025us + 10us - 260us
<[Trigger Pulse Width]
= [Trigger Pulse Width]+260us
2 (On)
IF
(1/ [Trigger Overlap=Off Readout Rate]) + 32.050us + 10us - 260us
≧ [Trigger Pulse Width]
=(1/[Trigger Overlap=Off Readout Rate]) + 32.050us + 10us
IF
(1/ [Trigger Overlap=Off Readout Rate]) + 32.050us + 10us - 260us
<[Trigger Pulse Width]
= [Trigger Pulse Width] + 260us
1 (Off)
IF
(1/ [Trigger Overlap=Off Readout Rate]) + 16.025us + 10us - 260us
≧ [Trigger Pulse Width]
= (1/[Trigger Overlap=Off Readout Rate]) + 16.025us + 10us
IF
(1/ [Trigger Overlap=Off Readout Rate]) + 16.025us + 10us - 260us
< [Trigger Pulse Width]
=[Trigger Pulse Width] + 260us
2 (On)
IF
(1/ [Trigger Overlap=Off Readout Rate]) + 32.050us + 10us - 260us
≧ [Trigger Pulse Width]
= (1/[Trigger Overlap=Off Readout Rate]) + 32.050us + 10us
IF
(1/ [Trigger Overlap=Off Readout Rate]) + 32.050us + 10us - 260us
<[Trigger Pulse Width]
=[Trigger Pulse Width] + 260us