IAI SP-20000C-USB User Manual page 58

20 mp cmos digital progressive scan monochrome and color camera spark series
Table of Contents

Advertisement

Table – 34 (Cont) Minimum trigger interval calculation formula (Trigger Overlap: Readout)
Camera Settings
Pixel
Binning
Format
Vertical
10 Bit
1 (Off)
Monochrome
Packed
/
10 Bit
Bayer
Packed
2 (On)
12 Bit
1 (Off)
Monochrome
Packed
/
12 Bit
Bayer
Packed
2 (On)
SP-20000M-USB / SP-20000C-USB
Trigger Mode="On"、Exposure Mode="Timed"、Trigger Overlap="Off"
Minimum Trigger Period setting calculation formula
[Unit:us]
IF
(1/[Trigger Overlap=Off Readout Rate]) +16.025us + 10us - 260us
≧ [Exposure Time]
= (1/[Trigger Overlap=Off Readout Rate]) + 16.025us + 10 us
IF
(1/[Trigger Overlap=Off Readout Rate]) +16.025us+ 10us - 260us
< [Exposure Time]
= [Exposure Time] + 260 us
IF
(1/[Trigger Overlap=Off Readout Rate]) +32.050 us+ 10us - 260us
≧ [Exposure Time]
= (1/[Trigger Overlap=Off Readout Rate]) + 32.050 us + 10us
IF
(1/[Trigger Overlap=Off Output Rate]) + 32.050 us + 10us - 260us
< [Exposure Time]
= [Exposure Time] + 260 us
IF
(1/[Trigger Overlap=Off Output Rate]) +16.025 us+ 10us - 260us
≧ [Exposure Time]
= (1/[Trigger Overlap=Off Output Rate]) + 16.025us + 10us
IF
[Trigger Overlap="Off" Output Period] +16.025 us+ 10us - 260us
< [Exposure Time]
= [Exposure Time] + 260 us
IF
(1/[Trigger Overlap=Off Output Rate]) +32.050 us + 10us - 260us
≧ [Exposure Time]
= (1/[Trigger Overlap=Off Output Rate]) +32.050us + 10us
IF
[Trigger Overlap="Off" Trigger Period] +32.050 us + 10us - 260us
< [Exposure Time]
= [Exposure Time] + 260 us