SP-20000M-USB / SP-20000C-USB
Acquisition Start
Set "Index 0"
Trigger In
Input
Execute Index Table
[Sequence
ROI
Frame
Count] Decrement value
— 1
[Sequence ROI
Frame Count]
Decrement
value
= 0
Next Index
= Off
[Sequence
Repetition]Decrement
value — 1
[Sequence
Repetition]
Decrement value
= 0
Acquisition Stop
Fig.36
No Input
>≠ 0
If Next Index does not
have OFF setting, the
seuqnce is continuously
repeated.
≠ Off
Index set for Next Index
>≠ 0
Sequence Trigger Flow Chart