Continuous; Acquisition Start; Acquisition Stop - IAI SP-20000C-USB User Manual

20 mp cmos digital progressive scan monochrome and color camera spark series
Table of Contents

Advertisement

7.1.1.3

Continuous

In this mode, when the AcquisitionStart command is set, the image is continuously output at the
current frame rate. This is the default setting for the SP-20000M-USB and SP-20000C-USB.
◆ Normal continuous operation
1) AcquisitionStart command is input
2) AcquisitionTriggerWait becomes effective
3) AcquisitionActive becomes "TRUE"
4) Images begin outputting continuously
5) AcquisitionStop command is sent
6) AcquisitionActive becomes "FALSE". At this moment, the output stops.
However, if AcqusitionStop command is initiated during image output period,
AcqusitionActive becomes "FALSE" (stop capturing) after image output is completed.
Note: This figure is if the trigger is set to ON, and when the trigger is OFF,
FrameActive becomes True at the same timing of AcquisitionActive.
◆ Forcing acquisition to stop
If AcquisitionStop is executed and the video is already output when the camera receives the
stop command, AcquisitionACtive becomes False (disabling the capture) after the video
output is completed.
Associated functions:AcquisitionStart、AcquisitionStop
7.1.2

Acquisition Start

This is the command to start the capture.
7.1.3

Acquisition Stop

This is the command to stop the capture.
SP-20000M-USB / SP-20000C-USB
Fig.25 Continuous operation
- 39 -

Advertisement