Table – 38 Minimum trigger interval calculation formula (Trigger Overlap = Readout)
Camera Settings
Pixel
Binning
Format
Vertical
1 (Off)
8 bit
Mono
chrome
/
8bit
Bayer
2 (On)
1 (Off)
10/12 bit
Mono
chrome
/
10/12 bit
Bayer
2 (On)
SP-20000M-USB / SP-20000C-USB
PWC Trigger / Trigger Overlap = Readout
[Unit:us]
IF
(1/[Trigger Overlap=Off Read Rate]) + 16.025 us + 10 us - 260 us
≧ [Trigger Pulse Width]
MIN.= (1/[Trigger Overlap=Off Read Rate]) + 16.025 us + 10 us
IF
(1/[Trigger Overlap=Off Readout Rate]) +16.025 us + 10 us - 260 us
<[Trigger Pulse Width]
MIN.= [Trigger Pulse Width]+260 us
IF
(1/[Trigger Overlap=Off Readout Rate]) + 32.050 us + 10 us - 260 us
≧ [Trigger Pulse Width]
MIN.=(1/[Trigger Overlap=Off Readout Rate]) + 32.050 us + 10 us
IF
(1/[Trigger Overlap=Off Readout Rate]) + 32.050 us + 10 us - 260 us
<[Trigger Pulse Width]
MIN.= [Trigger Pulse Width] + 260 us
IF
(1/[Trigger Overlap=Off Readout Rate]) + 16.025 us + 10 us - 260 us
≧ [Trigger Pulse Width]
MIN.= (1/[Trigger Overlap=Off Readout Rate]) + 16.025 us + 10 us
IF
(1/[Trigger Overlap=Off Readout Rate]) + 16.025 us + 10 us - 260 us
< [Trigger Pulse Width]
MIN.=[Trigger Pulse Width] + 260 us
IF
(1/[Trigger Overlap=Off Readout Rate]) + 32.050 us + 10 us - 260 us
≧ [Trigger Pulse Width]
MIN.= (1/[Trigger Overlap=Off Readout Rate]) + 32.050 us + 10 us
IF
(1/[Trigger Overlap=Off Readout Rate]) + 32.050 us + 10 us - 260 us
<[Trigger Pulse Width]
MIN.=[Trigger Pulse Width] + 260 us