YASKAWA SGMAS User Manual page 133

?-iii series servomotor
Table of Contents

Advertisement

7 Operation
7.1.1 Digital Operator Operation
(2) Parameter Set
Operation Key
B B
F n 0 0 1
F n 0 0 2
F n 0 0 3
F n 0 0 4
B B
P n 3 0 4 = 0 0 5 0 0
U n 0 0 0 =
U n 0 0 2 =
U n 0 0 D = 0 0 0 0 0 0 0 0
B B
P n 4 0 3 = 0 8 0 0 0
U n 0 0 0 =
U n 0 0 2 =
U n 0 0 D = 0 0 0 0 0 0 0 0
B B
P n 4 0 3 = 0 8 0 0 0
U n 0 0 0 =
U n 0 0 2 =
U n 0 0 D = 0 0 0 0 0 0 0 0
B B
P n 4 0 3 = 0 0 2 0 0
U n 0 0 0 =
U n 0 0 2 =
U n 0 0 D = 0 0 0 0 0 0 0 0
B B
F n 0 0 1
F n 0 0 2
F n 0 0 3
F n 0 0 4
Note: 1. For more information on operating method, refer to the Σ-III series SGM S/SGDS Digital Operator
Instructions (Manual No. TOBP S800000 01).
2. Some parameters require the power supply to be turned OFF and then turned ON again to enable the func-
tion. See 10.1.1 List of Parameters for full listing.
7-4
Display
- F U N C T I O N -
- J O G -
0 0 0 0 0
0 0 0 0 0
- J O G -
0 0 0 0 0
0 0 0 0 0
- J O G -
0 0 0 0 0
0 0 0 0 0
- J O G -
0 0 0 0 0
0 0 0 0 0
- F U N C T I O N -
Description
Display the main menu of the utility function mode, and select
the utility function Fn002.
Press the
Key.
Then, the screen changes and shows switches to the execution
* If the screen does not change, and NO-OP is displayed in
the status display section, a write prohibited password has
been saved in Fn010. Clear the write prohibited password if
possible.
Press the
Key or the
parameter number digit.
Press the
Key or the
value.
Press the
Key.
Cursor moves from the parameter number to the parameter
value.
Press the
Key or the
value digit.
Press the
Key or the
value.
Press the
Key.
Returns to the main menu of the auxiliary function mode.
Key to select the appropriate
Key to change the digit
Key to select the appropriate
Key to change the digit

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmpsSgmssSgmcs

Table of Contents