Using More Than One Servopack - YASKAWA SGMAS User Manual

?-iii series servomotor
Table of Contents

Advertisement

5.4.3 Using More Than One SERVOPACK

The following diagram is an example of the wiring when more than one SERVOPACK is used.
Connect the alarm output (ALM) terminals for the three SERVOPACKs in series to enable alarm detection relay
1RY to operate.
When the alarm occurs, the ALM output signal transistor is turned OFF.
Multiple servos can share a single molded-case circuit breaker (QF) or noise filter. Always select a QF or noise
filter that has enough capacity for the total power capacity (load conditions) of those servos. For details, refer to
2.5.2 Molded-case Circuit Breaker and Fuse Capacity.
Power supply
R S T
QF
Noise
filter
1KM
Note: Wire the system so that the power supply's phase-S is the ground.
Power
Power
ON
OFF
1RY
1KM
1KM
PRT
L1
L2
L3
SERVOPACK
L1C
L2C
+24V
CN1
1RY
13 ALM+
14 ALM -
L1
L2
L3
SERVOPACK
L1C
L2C
CN1
13 ALM+
14 ALM -
L1
L2
L3
SERVOPACK
L1C
L2C
CN1
13 ALM+
14 ALM -
0V
5.4 Special Wiring
Servomotor
M
Servomotor
M
Servomotor
M
5-17
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgmpsSgmssSgmcs

Table of Contents