3 SERVOPACK Specifications and Dimensional Drawings

3.2 SERVOPACK Installation

The SGDS SERVOPACKs can be mounted on a base or on a rack. Incorrect installation will cause problems.
Always observe the following installation instructions.
• Do not touch terminals for five minutes after voltage resistance test. (Refer to Voltage Resistance Test on the
next page.)
Residual voltage may cause electric shock.
• Connect the main circuit wires, control wires, and main circuit cables of the motor correctly.
Incorrect wiring will result in failure of the SERVOPACK.
Storage
Operating
Conditions
Installation Site Installation in a Control Panel
3-4
Store the SERVOPACK within the following temperature range if it is stored with the power cable dis-
connected.
Temperature: -20 to 85°C (-4 to 185°F)
Humidity: 90%RH or less (with no condensation)
• Installation category (Overvoltage category)
• Pollution degree
: 2
• Protection class
: 1X
• Altitude : 1000 m max.
* Conforming to the following standards.
Certification is pending for the following standards.
• UL508C
• CSA C22.2 No.14
• EN50178
• EN55011 group 1 class A
• EN61000-6-2
Design the control panel size, unit layout, and cooling method so the temperature around the
SERVOPACK does not exceed 55
Installation Near a Heating Unit
Minimize the heat radiating from the heating unit as well as any temperature rise caused by natural
convection so the temperature around the SERVOPACK does not exceed 55
Installation Near a Source of Vibration
Install a vibration isolator beneath the SERVOPACK to avoid subjecting it to vibration.
Installation at a Site Exposed to Corrosive Gas
Corrosive gas does not have an immediate effect on the SERVOPACK but will eventually cause the
electronic components and contactor-related devices to malfunction. Take appropriate action to avoid
corrosive gas.
Other Situations
Do not install the SERVOPACK in hot, humid locations or locations subject to excessive dust or iron
powder in the air.
WARNING
: ΙΙ
°
°
C (131
F).
°
°
C (131
F).