CHAPTER 12 DEVICE ADMINISTRATION

Automatically rebooting the device

To specify the amount of time that passes before the device automatically reboots itself:
1.
Go Administration > Debug Options > Auto Reboot Timer, select DISABLED, HOUR OF DAY, and TIMER
from the drop-down list under Auto Reboot.
2.
In the Auto Reboot Timer field, select the Hour of the Day (0-23) and then enter Hour of the Day to
Restart (0-23).
3.
If you do NOT want the device to automatically reboot, set the time to 0. The default setting is 0.

Setting up Telnet

To enable and configure Telnet on your device:
1.
Go to Administration > Debug Options > Telnet, check Enabled.
2.
Enter the Port number for Telnet.
3.
Enter the Username.
4.
Enter the Password. Enter it again under Confirm Password.
5.
Click Submit.
6.
To save your settings, click Save and Restart.

Configuring Remote Syslog

To enable and configure Remote Syslog to capture and send log data from your device, first you must setup a log
request in DeviceHQ
Device Logs. After the request has been completed, return to the device administration software.
1.
To activate Remote Syslog, go to Administration > Debug Options > Logging under Remote Syslog, check
Enabled.
2.
To enable a remote server to receive and store the router's log data, in the IP Address field, type the IP
address of the desired server.
3.
To determine the amount of log information that is collected, in the Debug Log Level, select the type of
information from the values in the dropdown menu which includes: Minimum, Error, Warning, Info,
Debug, and Maximum. The system will collect the type of information you specify. For example,
Maximum will collect all the log data available while Warning will collect anything that is a warning or
above that level.
4.
To download syslog information directly from the device, click Download.
5.
Click Submit.
6.
To save your changes, click Save and Restart.

Statistics Settings

To configure Statistics:
1.
Go to Administration > Debug Options > Statistics.
2.
Enter the Save Timeout in seconds.
3.
Enter the Save Data Limit in megabytes.
4.
To delete cell activity history, click Delete Cellular History.
5.
To delete ethernet history, click Delete Ethernet History.
6.
Click Submit.