Extreme Networks SSA-G8018-0652 Hardware Installation Manual page 55

S-series stand alone
Table of Contents

Advertisement

The rail and mid-bracket assemblies used in the two-post rack configuration (see
Mount Installation
The adapter plates can be installed in either a flush or a recessed configuration of up to 3.8 cm (1.5 in.).
The SSA switch can be configured for air intake on either the chassis switch I /O port side or the power
supply side. Adapter plate installation must align the adapter plate ears with the air intake side of the
chassis.
If you have not verified the power supply and fan module airflow for the chassis you are installing, see
Power Supply Airflow and Switch Fan Module Airflow
direction for your chassis before installing the adapter plates.
If the current fan module airflow direction does not match the intended chassis airflow direction, see
Reversing the Fan Module Airflow
To install the adapter plates, follow these steps:
1
Place the adapter plates on each side of the chassis with the ear end toward the air intake side of the
chassis, ear flange pointing away from the chassis.
Figure 23
shows the correct orientation for a chassis with airflow from switch I/O port side to power
supply side.
Figure 23: Installing the Adapter Plates
1 = Adapter plate (ear side)
2 = Flush mount adapter plate screw hole
S-Series Stand Alone (SSA) Switch Hardware Installation Guide
on page 59).
on page 15.
Optional Rack Mount Rail Kit Installation
on page 14 for information on determining airflow
3 = Recess mount adapter plate screw holes (1.5 in.)
4 = Airflow direction
Two-Post Rack
55