Error Assistance

4.
Error Assistance
At KEB COMBIVERT error messages are always represented with an "E." and the appropriate error in the
display. Error messages cause the immediate deactivation of the modulation. Restart possible only after reset or
autoreset.
Malfunction are represented with an „A." and the appropriate message. Reactions to malfunctions can vary. In the
following the display and their cause are described.
Display
COMBIVIS
Status Messages
bbL
base block
bon
close brake
boFF
open brake
Cdd
calculate drive
dcb
DC brake
dLS
low speed / DC brake
FAcc
forward acceleration
Fcon
forward constant
FdEc
forward deceleration
HCL
hardware current limit
LAS
LA stop
LdS
Ld stop
LS
low speed
nO_PU
power unit not ready
noP
no operation
PA
positioning active
PLS
low speed / power off
PnA
position not reachable
POFF
power off function
POSI
positioning
rAcc
reverse acceleration
rcon
reverse constant
rdEc
reverse deceleration
rFP
ready for positioning
SLL
stall
SrA
search for ref. active
SSF
speed search
STOP
quick stop
Value Meaning
76
Power modules for motor de-excitation locked
85
Brake control, brake engaged (see chapter 6.9)
86
Brake control, brake released (see chapter 6.9)
82
Measurement of the motor stator resistance.
75
Motor is decelerated by a DC-voltage at the output.
Modulation is switched off after DC-braking (see chapter 6.9 "DC-
77
Braking").
64
Acceleration with the adjusted ramps in clockwise direction of rotation.
Acceleration / deceleration phase is completed and it is driven with
66
constant speed / frequency in clockwise direction of rotation.
It is stopped with the adjusted ramp times in clockwise direction of
65
rotation.
The message is output if the output current reaches the hardware
80
current limit.
This message is displayed if during acceleration the load is limited to the
72
adjusted load level.
This message is displayed if during deceleration the load is limited to the
73
adjusted load level or the DC-link current to the adjusted voltage level.
70
No direction of rotation pre-set, modulation is off.
13
Power circuit not ready or not identified by the control.
0
Control release (terminal ST) is not switched.
122
This message is displayed during a positioning process.
84
No modulation after Power-Off.
The specified position cannot be reached within the pre-set ramps. The
123
abort of the positioning can be programmed.
Depending on the programming of the function (see chapter 6.9 „Power-
78
off Function) the inverter restarts automatically upon system recovery or
after a reset.
83
Positioning function active (F5-G).
Acceleration with the adjusted ramp times in anti-clockwise direction of
67
rotation.
Acceleration / deceleration phase is completed and it is driven with
69
constant speed / frequency in clockwise direction of rotation.
It is stopped with the adjusted ramp times in anti-clockwise direction of
68
rotation.
121
The drive signals that it is ready to start the positioning process.
This message is displayed if during constant operation the load is limited
71
to the adjusted current limit.
81
Search for reference point approach active.
Speed search function active, that means that the inverter attempts to
74
synchronize onto a running down motor.
The message is output if as response to a warning signal the quick-stop
79
function becomes active.
further on next side
GB - 25