APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 13 of 64)
ADDR
REGISTER NAME
2706
IEC 61850 Received uinteger 12
2708
IEC 61850 Received uinteger 13
270A
IEC 61850 Received uinteger 14
270C
IEC 61850 Received uinteger 15
270E
IEC 61850 Received uinteger 16
Expanded FlexStates (Read Only)
2B00
FlexStates, one per register (256 items)
Expanded Contact Input/Output States (Read Only)
2D00
Contact Input States, one per register (96 items)
2D80
Contact Output States, one per register (64 items)
2E00
Virtual Output States, one per register (96 items)
Expanded Remote Input/Output Status (Read Only)
2F00
Remote Device States, one per register (32 items)
2F80
Remote Input States, one per register (64 items)
Oscillography Values (Read Only)
3000
Oscillography Number of Triggers
3001
Oscillography Available Records
3002
Oscillography Last Cleared Date
3004
Oscillography Number Of Cycles Per Record
Oscillography Commands (Read/Write Command)
3005
Oscillography Force Trigger
3011
Oscillography Clear Data
Oscillography Analog Values (Read Only)
3012
Oscillography Number of Triggers
Fault Report Indexing (Read Only Non-Volatile)
3020
Number of Fault Reports
Fault Report Actual Values (Read Only Non-Volatile) (15 modules)
3030
Fault Report 1 Time
3032
Fault Report 2 Time
3034
Fault Report 3 Time
3036
Fault Report 4 Time
3038
Fault Report 5 Time
303A
Fault Report 6 Time
303C
Fault Report 7 Time
303E
Fault Report 8 Time
3040
Fault Report 9 Time
3042
Fault Report 10 Time
3044
Fault Report 11 Time
3046
Fault Report 12 Time
3048
Fault Report 13 Time
304A
Fault Report 14 Time
304C
Fault Report 15 Time
Modbus File Transfer (Read/Write)
3100
Name of file to read
Modbus File Transfer Values (Read Only)
3200
Character position of current block within file
3202
Size of currently-available data block
3203
Block of data from requested file (122 items)
Security (Read/Write Setting)
3280
Administrator Alphanumeric Password Setting
Security (Read Only)
328A
Administrator Alphanumeric Password Status
Security (Read/Write)
328B
Administrator Alphanumeric Password Entry
GE Multilin
RANGE
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 400000000
0 to 65535
0 to 1
0 to 1
0 to 32767
0 to 65535
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
---
0 to 4294967295
0 to 65535
0 to 65535
---
0 to 1
---
F35 Multiple Feeder Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F108
---
1
F108
---
1
F108
---
1
F108
---
1
F155
---
1
F108
---
1
F001
---
1
F001
---
1
F050
---
1
F001
---
1
F126
---
1
F126
---
1
F001
---
1
F001
---
1
F050
---
1
F050
---
1
F050
---
1
F050
---
1
F050
---
1
F050
---
1
F050
---
1
F050
---
1
F050
---
1
F050
---
1
F050
---
1
F050
---
1
F050
---
1
F050
---
1
F050
---
---
F204
---
1
F003
---
1
F001
---
1
F001
---
---
F202
---
1
F102
---
---
F202
DEFAULT
0
0
0
0
0
B
0 (Off)
0 (Off)
0 (Off)
0 (Off)
0 (Offline)
0 (Off)
0
0
0
0
0 (No)
0 (No)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
(none)
0
0
0
(none)
0 (Disabled)
(none)