APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 57 of 64)
ADDR
REGISTER NAME
C882
Platform Direct I/O Data Rate
C883
Direct I/O Channel 2 Ring Configuration Function
C884
Platform Direct I/O Crossover Function
Direct Input/Output Commands (Read/Write Command)
C888
Direct Input/Output Clear Counters Command
Direct inputs (Read/Write Setting) (32 modules)
C890
Direct Input 1 Device Number
C891
Direct Input 1 Number
C892
Direct Input 1 Default State
C893
Direct Input 1 Events
C894
...Repeated for Direct Input 2
C898
...Repeated for Direct Input 3
C89C
...Repeated for Direct Input 4
C8A0
...Repeated for Direct Input 5
C8A4
...Repeated for Direct Input 6
C8A8
...Repeated for Direct Input 7
C8AC
...Repeated for Direct Input 8
C8B0
...Repeated for Direct Input 9
C8B4
...Repeated for Direct Input 10
C8B8
...Repeated for Direct Input 11
C8BC
...Repeated for Direct Input 12
C8C0
...Repeated for Direct Input 13
C8C4
...Repeated for Direct Input 14
C8C8
...Repeated for Direct Input 15
C8CC
...Repeated for Direct Input 16
C8D0
...Repeated for Direct Input 17
C8D4
...Repeated for Direct Input 18
C8D8
...Repeated for Direct Input 19
C8DC
...Repeated for Direct Input 20
C8E0
...Repeated for Direct Input 21
C8E4
...Repeated for Direct Input 22
C8E8
...Repeated for Direct Input 23
C8EC
...Repeated for Direct Input 24
C8F0
...Repeated for Direct Input 25
C8F4
...Repeated for Direct Input 26
C8F8
...Repeated for Direct Input 27
C8FC
...Repeated for Direct Input 28
C900
...Repeated for Direct Input 29
C904
...Repeated for Direct Input 30
C908
...Repeated for Direct Input 31
C90C
...Repeated for Direct Input 32
Direct Input/Output Alarms (Read/Write Setting)
CAD0
Direct Input/Output Channel 1 CRC Alarm Function
CAD1
Direct Input/Output Channel 1 CRC Alarm Message Count
CAD2
Direct Input/Output Channel 1 CRC Alarm Threshold
CAD3
Direct Input/Output Channel 1 CRC Alarm Events
CAD4
Reserved (4 items)
CAD8
Direct Input/Output Channel 2 CRC Alarm Function
CAD9
Direct Input/Output Channel 2 CRC Alarm Message Count
CADA
Direct Input/Output Channel 2 CRC Alarm Threshold
CADB
Direct Input/Output Channel 2 CRC Alarm Events
CADC
Reserved (4 items)
CAE0
Direct Input/Output Ch 1 Unreturned Messages Alarm
Function
GE Multilin
RANGE
64 to 128
0 to 1
0 to 1
0 to 1
0 to 16
0 to 96
0 to 3
0 to 1
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
F35 Multiple Feeder Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
kbps
64
F001
---
1
F126
---
1
F102
---
1
F126
---
1
F001
---
1
F001
---
1
F086
---
1
F102
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
DEFAULT
64
0 (No)
0 (Disabled)
0 (No)
B
0
0
0 (Off)
0 (Disabled)
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
B-65