Control connection 4 - Forward/Reverse.
Enabling the Forward/Reverse function.
Parameters to set:
Set DI3 to FORWARD
P0265 = 4
Set DI4 to REVERSE
P0266 = 5
When the Forward/Reverse function is set, it will be active either in Local or Remote mode. At the same time,
the operator keys
and
The direction of rotation is determined by the Forward and Reverse inputs.
Clockwise to forward and counter-clockwise to reverse.
The speed reference can be provided by any source (as in control connection #3).
Stop/Forward S1
Stop/Reverse S2
will remain always inactive (even if P0224 = 0 or P0227 = 0).
Connector XC1
1
+ REF
2
AI1+
3
AI1-
4
- REF
5
AI2+
6
AI2-
7
AO1
8
AGND (24 V)
9
AO2
10
AGND (24 V)
11
DGND *
12
COM
13
24 Vcc
14
COM
15
DI1
16
DI2
17
DI3
18
DI4
19
DI5
20
DI6
21
NF1
22
C1
23
NA1
24
NF2
25
C2
26
NA2
27
NF3
28
C3
29
NA3
Figure 3.26 - XC1 wiring for control connection #4
Installation and Connection
DO1
(RL1)
DO2
(RL2)
DO3
(RL3)
3
CFW-11 | 3-33