Installation and Connection
Connector XC1
CW
≥5 kΩ
CCW
rpm
3
amp
3-26 | CFW-11
Factory Default Function
1
+REF Positive reference for
potentiometer
2
AI1+
Analog input 1:
speed reference (remote)
3
AI1-
4
REF-
Negative reference for
potentiometer
5
AI2+
Analog input 2:
no function
6
AI2-
7
AO1
Analog output 1:
speed
8
AGND
Reference (0 V) for the analog
(24 V)
outputs
9
AO2
Analog output 2:
motor current
10
AGND
Reference (0 V) for the analog
(24 V)
outputs
11
DGND * Reference (0 V) for the 24 Vdc
power supply
12
COM Common point of the digital
inputs
13
24 Vdc 24 Vdc power supply
14
COM Common point of the digital
inputs
15
DI1
Digital input 1:
Start/Stop
16
DI2
Digital input 2:
direction of rotation (remote)
17
DI3
Digital input 3:
no function
18
DI4
Digital input 4:
no function
19
DI5
Digital input 5:
Jog (remote)
20
DI6
Digital input 6:
2
ramp
nd
21
NC1
Digital output 1 DO1 (RL1):
no fault
22
C1
23
NO1
24
NC2
Digital output 2 DO2 (RL2): N
> N
- Speed > P0288
25
C2
X
26
NO2
27
NC3
Digital output 3 DO3 (RL3):
N* > N
- Speed reference >
28
C3
X
P0288
29
NO3
(a) Digital inputs working as "Active High"
Specifications
Output voltage:+5.4 V, ±5 %
Maximum output current: 2 mA
Differential
Resolution: 12 bits
Signal: 0 to 10 V (R
= 400 kΩ) / 0 to 20 mA / 4 to 20 mA (R
IN
Maximum voltage: ±30 V
Output voltage: -4.7 V, ±5 %
Maximum output current: 2 mA
Differential
Resolution: 11 bits + signal
Signal: 0 to ±10 V (R
= 400 kΩ) / 0 to 20 mA / 4 to 20 mA (R
IN
Maximum voltage: ±30 V
Galvanic Isolation
Resolution: 11 bits
Signal: 0 to 10 V (R
≥ 10 kΩ) / 0 to 20 mA / 4 to 20 mA (R
L
Protected against short-circuit
Connected to the ground (frame) through an impedance: 940 Ω resistor
in parallel with a 22 nF capacitor. Same reference as the one of DGND *
Galvanic Isolation
Resolution: 11 bits
Signal: 0 to 10 V (R
≥ 10 kΩ) / 0 to 20 mA / 4 to 20 mA (R
L
Protected against short-circuit
Connected to the ground (frame) through an impedance: 940 Ω resistor
in parallel with a 22 nF capacitor. Same reference as the one of DGND *
Connected to the ground (frame) through an impedance: 940 Ω resistor
in parallel with a 22 nF capacitor. Same reference as the one of AGND (24 V)
24 Vdc power supply, ±8 %
Capacity: 500 mA
Note: In the models with the 24 Vdc external control power supply
(CFW11...O...W...) pin 13 o XC1 is considered na input, that is, the user must
provide a supply for the inverter (for further details refer to
External Control Power Supply on page 7-2
models this terminal is an output, i.e., the user has a 24 Vdc power supply
available there
6 isolated digital inputs
High level ≥ 18 V
Low level ≤ 3 V
Maximum input voltage = 30 V
Input current: 11 mA @ 24 Vdc
Contact rating:
Maximum voltage: 240 Vac
Maximum current: 1 A
NC - normally closed contact
C - common
NO - normally open contact
= 500 Ω)
IN
= 500 Ω)
IN
≤ 500 Ω)
L
≤ 500 Ω)
L
Item 7.1.5 24 Vdc
for more details). In all the other

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents