Circulating Pump; Low Loss Header - DeDietrich C 230 ECO Installation And Service Manual

Gas fired condensing boiler
Hide thumbs Also See for C 230 ECO:
Table of Contents

Advertisement

4.4.5

Circulating pump

The C 230 ECO is not fitted with one of these, but the DIEMATIC-m3
makes it possible to control a external pump.
4.4.6

Low loss header

Please refer to the prevailing regulations in your country.
Low loss header
Useful output output
kW
80
120
160
200
240
280
320
360
400
440
480
520
560
600
640
30
Flow rate
Ø D
3
inch
m
/h
3.4
3
5.2
4
6.9
4
8.6
5
10.3
5
12.0
6
13.8
6
15.5
6
17.2
8
18.9
8
20.6
8
22.4
8
24.1
8
25.8
8
27.5
10
The water resistance at T to 20 K is as follows:
C 230-85
C 230-130
C 230-170
C 230-210
Boiler side
Installation side
Square D
d interior
DN
mm
inch
80
70
1 1/4
100
90
100
100
125
110
2 1/2
125
120
2 1/2
150
130
2 1/2
150
140
2 1/2
150
150
2 1/2
200
160
2 1/2
200
170
200
170
200
180
200
190
200
190
250
200
C 230 ECO
165 mbar
135 mbar
170 mbar
180 mbar
H
mm
mm
280
370
2
350
465
2
350
465
440
580
440
580
440
580
440
580
440
580
440
580
3
540
720
3
540
720
3
540
720
3
540
720
3
540
720
3
540
720
03/10/2012 - 300015171-001-01
A
B
mm
510
630
630
770
770
770
770
770
770
900
900
900
900
900
900

Hide quick links: