7.2.3

Checking tightness (hydraulics, combusted gas discharge and gas)

Checking for leaks (water, combusted gas, gas).
7.2.4

Checking the hydraulic pressure

The hydraulic pressure must be a minimum of 0.8 bars. The hydraulic
pressure depends on the static height higher than the boiler (static
pressure, 1 bar = 10 metres C.E.). We recommend filling the
installation to around 0.8 bars higher than the static height.

7.3 Maintenance

When the boiler is fouled, carry out the following maintenance
operations.
- Clean the fan
- Clean the heat exchanger using the tool provided
- Clean the burner
- Clean the siphon
Before working on the appliance, ensure that the shut-off
valve is closed and that the mains supply to the boiler is
disconnected.