Setting The Calibration Display Level; Setting The Calibration; Setting The Status Message; Setting The Auto Clear Function - Toshiba E-STUDIO477S Advanced Manual

Multifunctional digital systems
Hide thumbs Also See for E-STUDIO477S:
Table of Contents

Advertisement

SETTING ITEMS (ADMIN)

Setting the calibration display level

You can set whether this equipment will use the calibration
1
setting set by a user or the administrator.
The relevant buttons ([CALIBRATION]) will appear under the
ADMIN menu only or under both the USER and ADMIN menus
according to this setting.
Item name
CALIBRATION
• USER — Press this button to display
2
• ADMIN — Press this button to display

Setting the calibration

You can automatically calibrate the gradation when the
shading is not reproduced accurately in the images scanned by
3
this machine.
Note
• Whether to allow calibration by not only administrators but
also users, is set by DISPLAY LEVEL.
P.166 "Setting the calibration display level"
• Place LT or A4 paper (recommended paper) in the drawer
before starting the calibration. If any other paper is used,
4
calibration may not be performed properly.
• If the glass is dirty or any foreign objects are stuck to it,
calibration may not be performed properly. Keep the glass
clean.
• Do not raise the Reversing Automatic Document Feeder, or
open the front cover while the calibration is in progress. If
this does happen, calibration cannot be finished properly.
• Interrupt copying is not available during the calibration.
5
Memo
• For instructions on how to display the CALIBRATION
screen, see the following page:
P.139 "Accessing the User Menu"
1
Press [COPY].
6
2
Select the paper type and press [OK].
Note
• Depending on the machine settings, the screen to
select the paper type may not be displayed. In this
case, proceed to the next step.
7
Description
[CALIBRATION] in the ADMIN menu
as well as the USER menu.
[CALIBRATION] in the ADMIN menu.
3
Select the calibration settings.
Item name
DEFAULT
CALIBRATION
4
Place the printed chart face down on the
glass, so that the two black rectangular
marks are placed on the left side.
5
Press the [START] button on the control
panel.
The calibration begins. Do not operate the equipment
until the message "Scanning and calibrating" disappears.
Note
• If the chart is not properly placed, the message "Set
chart correctly" is displayed on the touch panel. In this
case, return to step 3 and realign the chart.

Setting the status message

You can have a status message displayed at the bottom of the
touch panel, notifying the occurrence of specified events, such
as paper empty and toner low.
Press [ON] or [OFF] for each status message and press [OK].
Item name
SUPPLIES
Enabling this option displays a message
NEAR LIFE
at the lower left of the screen when
MESSAGE
supplies such as toner, image drum, fuser
unit and belt unit nears the end of their
lifespan.
PAPER EMPTY
Enabling this option displays a message
MESSAGE
at the lower left of the screen when there
is no paper in a drawer.

Setting the auto clear function

You can set how long the machine waits before clearing the
previous operation left uncompleted on the control panel.
Press the desired period of time (in seconds). If you want to
disable the Auto Clear function, press [NO LIMIT].
- 166 -
Description
Press this button to restore the
default calibration setting and return
to the previous screen.
Press this button to calibrate using
the printed chart. In this case,
proceed to the next step.
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio477slE-studio527sE-studio477s

Table of Contents