FX
Series Programmable Controllers
3UC
User's Manual - Hardware Edition
Counter
High-speed
counter
Data register
(32 bits when
paired)
Extension register (16 bits)
Extension file register (16 bits)
Pointer
Nesting
Constant
Item
Increment for general
C0 to C99
(16 bits) [changeable]
Increment for keeping
C100 to C199
(16 bits) [changeable]
Both directions for
general (32 bits)
C200 to C219
[changeable]
Increment for keeping
C220 to C234
(32 bits) [changeable]
1-phase 1-count input
in both directions (32
C235 to C245
bits) [changeable]
1-phase 2-count input
in both directions (32
C246 to C250
bits) [changeable]
2-phase 2-count input
in both directions (32
C251 to C255
bits) [changeable]
For general (16 bits)
D0 to D199
[changeable]
For keeping (16 bits)
D200 to D511
[changeable]
For keeping (16 bits)
D512 to D7999
[fixed]
<D1000 to
<File register>
D7999>
For special (16 bits)
D8000 to D8511 512 points
V0 to V7
For index (16 bits)
Z0 to Z7
R0 to R32767
ER0 to
ER32767
For branching of JUMP
P0 to P4095
and CALL
Input interruption and
input delay
I0
interruption
Timer interruption
I6
Counter interruption
I010 to I060
For master control
N0 to N7
16 bits
Decimal number (K)
32 bits
16 bits
Hexadecimal number
(H)
32 bits
Real number (E)
32 bits
Character string (" ")
Character string
Performance
100 points
Counting from 0 to 32,767
The retentive status can be changed
by parameter settings.
100 points
Counting from -2,147,483,648 to
20 points
+2,147,483,647
The retentive status can be changed
by parameter settings.
15 points
Up to 8 points can be used in range from C235 to
C255. [For keeping]
The retentive status can be changed by parameter
settings.
Counting from -2,147,483,648 to +2.147,483,647
Hardware counter
1-phase: 100 kHz x 6 points, 10 kHz x 2 points
2-phase: 50 kHz (multiply by 1), 50 kHz (multiply by 4)
Software counter
1-phase: 40kHz
2-phase: 40 kHz (multiply by 1), 10 kHz (multiply by 4)
200 points
The retentive status can be changed
by parameter settings.
312 points
D1000 and later in 7488 points of
fixed data register for keeping can be
7488 points
set as file register points in 500-point
<7000 points>
units by changing the parameter
settings.
16 points
Retained by battery during power
32768 points
failure
Usable only when memory cassette
32768 points
is mounted
For CJ instructions and CALL
4096 points
instructions
to I5
6 points
to I8
3 points
6 points
For HSCS instructions
8 points
For MC instructions
-32,768 to +32,767
-2,147,483,648 to +2,147,483,647
0 to FFFF
0 to FFFFFFFF
128
-1.0 x 2
to -1.0 x 2
Decimal-point and exponential notations are possible.
Designation by characters enclosed with " "
Up to 32 one-byte characters can be used for a
constant in an instruction.
B Performance Specifications
-126
-126
128
, 0, 1.0 x 2
to 1.0 x 2
423
11
12
A
B
C
D
E
F