Connecting To The Contact Closure Or Cue Tone Interfaces - Cisco D9040 User And Service Manual

Table of Contents

Advertisement

Connecting to the Contact Closure or Cue Tone Interfaces

Contact Closure and Cue Tone Connector
The D9040 Encoder has a contact closure and a cue tone interface (not used), which
can be used to trigger digital program insertion (DPI). The contact closure interface
has 8 inputs. The cue tone interface has two inputs.
Pin Allocation
The connector labeled CUE CON CLO is a 24-pin terminal block connector.
The following table shows the connector and the pin allocation.
Connector Drawing
Note: Contact open = not connected (internal pull-up).
Contact closed = connected to ground.
To Connect to the Contact Closure Interface
Connect the external contact closure equipment to the contact closure interface.
External contact closure equipment could be a Monroe DTMF decoder.
To Connect to the Cue Tone Interface
Connect the external cue tone equipment to the cue tone interface. External cue tone
equipment could be a PowerVu
3-12
Pin
Description
Number
1
Cue Tone In + 13
2
Cue Tone In - 14
3
Ground
4
NC
5
Contact 1
6
Ground
7
Contact 2
8
Ground
9
Contact 3
10
Ground
11
Contact 4
12
Ground
(not used)
®
D9850 Program Receiver.
Installation
Pin
Description
Number
NC
NC
15
NC
16
INC
17
Contact 5
18
Ground
19
Contact 6
20
Ground
21
Contact 7
22
Ground
23
Contact 8
24
Ground
4020024 Rev C