Message
Description and Remedy
TS rate/Video
Description: The encoding rate is too high
rate mismatch.
compared to the TS rate or the encoding
rate is too low. The encoding will restart.
Remedy: Check the settings. Change the
encoding rate or increase the TS rate. In a
statmux set-up, the TS rate of an encoder
must have room for the maximum
instantaneous encoding rate. If a FIFO
error occurs recurrently, contact your
Cisco technical support
center.
VII error.
Description: The encoder has detected an
error in the VII signal. Remedy: Check
your SDI source and the equipment that
generates VII.
VITC input loss.
Description: The VITC signal in the video
input signal has disappeared. Remedy:
Check your video source and the
equipment that generates VITC.
VPS input loss.
Description: The VPS signal in the video
input signal has disappeared. Remedy:
Check your video source and the
equipment that generates VPS.
WSS input loss.
Description: The WSS signal in the video
input signal has disappeared. Remedy:
Check your video source and the
equipment that generates WSS.
5-16
Service and Maintenance
Severity
Default
alarm
category
Major
B
Major
None
Major
None
Major
None
Major
None
4020024 Rev C
Enable
On
Off
Off
Off
Off