Cisco D9040 User And Service Manual page 89

Table of Contents

Advertisement

Message
Description and Remedy
Subcarrier
Description: The input is not able to lock
unlock.
to the subcarrier. Remedy: The frequency
offset is likely too high. Color
reproduction may suffer. Check your
video source.
Sync unstable.
Description: The composite video
synchronization signal is unstable.
Remedy: Check the video source or use a
frame synchronizer.
System boot
Description: System boot has been
completed.
completed. Remedy: Not applicable.
Teletext input
Description: The teletext signal has
loss.
disappeared from the input. Remedy:
Check your video source and the
equipment that generates teletext.
Temperature
Description: The temperature is
approaching high
approaching the upper limit for safe
limit.
operation. Remedy: Check that the Fan
malfunction message is enabled and not
active. Apply external cooling if the
ambient temperature is above 45 degrees
Celsius.
Temperature
Description: The temperature is
approaching low
approaching the lower limit for safe
limit.
operation. Remedy: Raise the ambient
temperature to more than 0 (zero)
degrees Celsius.
Temperature
Description: The temperature is outside
outside safe
the safe limits. The unit will be shut
limits.
down. Remedy: Check that the Fan
malfunction message is enabled and not
active. Check that the ambient
temperature is within 0 - 45 degrees
Celsius.
The option
Description: An option license file is
import string is
invalid. Remedy: Check the Host ID and
invalid.
the ordered options in the option license
file.
4020024 Rev C
Service and Maintenance
Severity
Default
alarm
category
Major
B
Major
B
Information None
Major
None
Warning
B
Warning
B
Critical
A
Information None
Enable
On
On
On
Off
On
On
On
On
5-15