7)
An end of the calibration of a motor drive will start automatic compensation. Since it rectifi es carrying out a simultaneous drive so
that travel time may become as uniform as possible, don't touch a fader until it ends.
8)
Since the [APPLY] button is displayed on a screen after all are completed, it checks that all of SEL-LED of each fader upper part,
CUE-LED, and ON-LED have gone out, and pushes the [APPLY] button. Although it returns to the screen of Procedure 1), it is
displayed as [RESTART] and can also carry out again.
2. Error
Carry out the following correspondence, when at least one LED is on at the time of the above-mentioned procedure 8).
1) SEL-LED is on:
The alignment of either of four places of the above-mentioned procedures 2) - 5) has gone wrong.
Since the [CANSEL] button and the [APPLY] button are displayed on an LCD screen, perform [CANSEL] if needed and redo from
Procedure 1).
2) CUE-LED is on:
It cannot be fi nishing moving by the above-mentioned procedure 6) with the regulation maximum voltage.
Since the [APPLY] button is displayed on an LCD screen, once push, and after that, redo the fader concerned from Procedure 1)
anew after performing about 10 times of moving by hand.
3) CUE-LED and ON-LED are on:
Oscillation vibration was caused in the midst of the above-mentioned procedure 6).
Exchange the fader concerned.
TF5/TF3/TF1
195