7-10-2. SW_PNC
[Contents]
Inspect the switches on the PNC circuit board.
It judges by detecting operation of the target switches.
[Procedure]
<GUI>
Operate switches on sheet PNC.
ABORT
Popup dialog as shown in the above fi gure is displayed on
the screen. Operate the switches which have been the targets
of the inspection.
LED built in the target switch turns on. If operation is
detected, LED will turn off.
The following LEDs are substituted for the switch built in
the encoder.
UDEF KNOB A – > METER -25
UDEF KNOB B – > METER -30
UDEF KNOB C – > METER -40
UDEF KNOB D – > METER -50
TOUCH AND TURN KNOB – > METER -60
If operation of all the switches is detected, popup dialog will
be closed automatically.
When popup dialog does not close in spite of having operated
it, push the [ABORT] button. Close the popup dialog.
7-10-3. SW_PNFD1
[Contents]
Inspect the switches on the PNFD1 circuit board.
It judges by detecting operation of the target switches.
[Procedure]
<GUI>
Operate switches on sheet PNFD1.
ABORT
Popup dialog as shown in the above fi gure is displayed on
the screen. Operate the switches which have been the targets
of the inspection.
LED built in the target switch turns on. If operation is
detected, LED will turn off.
If operation of all the switches is detected, popup dialog will
be closed automatically.
When popup dialog does not close in spite of having operated
it, push the [ABORT] button. Close the popup dialog.
7-10-4. SW_PNF
[Contents]
Inspect the switches on the PNF circuit board.
It judges by detecting operation of the target switches.
[Procedure]
<GUI>
Operate switches on sheet PNF.
ABORT
Popup dialog as shown in the above fi gure is displayed on
the screen. Operate the switches which have been the targets
of the inspection.
LED built in the target switch turns on. If operation is
detected, LED will turn off.
If operation of all the switches is detected, popup dialog will
be closed automatically.
When popup dialog does not close in spite of having operated
it, push the [ABORT] button. Close the popup dialog.
7-10-5. SW_FD8_1 (CH1-CH8)
[Contents]
Inspect the switches on the PNFD8 circuit board (CH1-8).
It judges by detecting operation of the target switches. "
[Procedure]
<GUI>
Operate switches on sheet FD8(CH01-08).
ABORT
Popup dialog as shown in the above fi gure is displayed on
the screen. Operate the switches which have been the targets
of the inspection.
LED built in the target switch turns on. If operation is
detected, LED will turn off.
If operation of all the switches is detected, popup dialog will
be closed automatically.
When popup dialog does not close in spite of having operated
it, push the [ABORT] button. Close the popup dialog.
7-10-6. SW_FD8_2 (CH9-CH16)
7-10-7. SW_FD8_3 (CH17-CH24)
7-10-8. SW_FD8_4 (CH25-CH32)
[Contents]
Although the target of the inspection replaces CH9-16,
CH17-24 or CH25-32, the contents are the same as that of
"7-10-5. SW_FD8_1".
"7-10-7. SW_FD8_3" function is for TF5 and TF3.
"7-10-8. SW_FD8_4" function is for TF5 only.
TF5/TF3/TF1