Vaisala PWD22 User Manual page 116

Present weather detector
Hide thumbs Also See for PWD22:
Table of Contents

Advertisement

User's Guide _______________________________________________________________________
Status Message Typical
P12
Positive voltages
11.5 V
of the DC/DC
converter for the
transmitter and
receiver
M12
Negative
-11.5 V
voltages of the
DC/DC converter
for the transmitter
and receiver
DRD
Instant value of
64...900Hz 64 / DRY
®
RAINCAP
Rain
Sensor
BL
Background
4...20000
luminance
cd/m²
RELAYS
States of the
ON / OFF
three external
relays controls
HOOD HEATERS
Hood heater
ON / OFF
automatics is
switched either
on or off.
114___________________________________________________________________ M210543EN-B
Min. / Max.
Fault
10 V / 14 V
<10.0 V
>14.0 V
'+-12 V
POWER
ERROR'
-14 V / -10 V <-14.0 V
>-10.0 V
'+-12 V
POWER
ERROR'
< 64 Hz
'DRD ERROR'
4 cd/m² /
'LUMINANCE
20000 cd/m²
SENSOR
ERROR'
-
-
Description
Action
DC/DC converter
1) Reset
is overloaded or
2) Disconnect
working wrong.
transmitter
P12 measurement
3) Change the
may also fail due
PWC22
to heavy
control unit.
electrostatic
discharge to
®
RAINCAP
plate.
DC/DC converter
1) Reset
is overloaded or
2) Disconnect
working wrong.
transmitter
M12 measurement
3) Change the
may also fail due
PWC22
to heavy
control unit.
electrostatic
discharge to
®
RAINCAP
plate.
Cable
1) Check
disconnected or
connector X7
rain detector
and X6 on the
®
RAINCAP
short-
PWC22
circuits
control unit.
2) Change the
RAINCAP
Rain Sensor.
Cable
Check
disconnected or
connector X3
PWL111 short-
pins 1,2,3,4.
circuits
-
-
If set to ON state,
Heaters can
heater current
be tested by
starts flowing when
the HEAT ON
ambient
command.
temperature goes
Warming of
below +2°C and
the heater
stops when it
foils should be
raises over +5°C.
felt by hand. If
not check
powering and
cabling.
®