Charging System; If The Charging System Is Not Working; Continuity Of 10A Fuse; Battery Charging Voltage - Malaguti F12R L.C. 50 cc Workshop Manual

Table of Contents

Advertisement

F12R L.C. 50 cc.
If the charging system is not working, check:
1)

CONtINUItY OF 10a FUSe

)

BatterY CharGING VOLtaGe

3)
CharGING COIL reSIStaNCe
4)
CONNeCtIONS OF reCharGING SYSteM
1. continuity of 10a fuse
- remove fuse.
- Connect Tester (Ω) to fuse.
- Check continuity of fuse.
- Not compliant: replace fuse.
F. 18
2. Battery charging voltage
- Connect inductive rev counter to spark plug cable
- Connect Tester (20 Vdc) to battery, as follows:
- terminal (+) of tester
- terminal (-) of tester
- Start engine and run it at 000 rpM.
- Check battery voltage.
- Charging voltage: 13.5 ~ 14.5 V.
- Not compliant: continue searching.
- NOTE: use a fully charged battery.
1
F. 19
0.07
ISSUe

Charging System

cHaRGING SySTEm
(+) terminal of battery (1).
(-) terminal of battery (2).
-
BATTERIA
Tester (Ω)
2
B
Chapter
Tester (dc 20 V)
1
paGe