F12R L.C. 50 cc.
If the mixture oil signal is not correct, check:
1)
OIL prOBe
)
VOLtaGe LeVeL CheCK
1. Oil probe
- Detach connector of oil probe and take it out of tank.
- Connect Tester (Ω) to connector, as follows:
- terminal (+) of tester
- terminal (-) of tester
- Check continuity of float (a). In there is continuity, the float will move freely and position itself at the base
of the probe.
- Not compliant: replace oil probe.
1
a
F. 47
2. check voltage level
- Connect Tester (20 V dc) to connector (system side), as follows:
- terminal (+) of tester
- terminal (-) of tester
- turn key "ON".
- Voltage delivered to oil probe: > 12 V.
- compliant: white/purple cable interrupted between probe and digital instrument (PIN 8). repair.
See "Wiring Diagram".
- Not compliant: blue cable interrupted. repair.
See "Wiring Diagram".
1
F. 48
0.07
ISSUe
Coupling (1).
Coupling (2).
2
Blue cable (1).
Chassis grounding (2).
BL
B/VL
Signalling System
2
B
Chapter
Tester (Ω)
Tester (dc 20 V)
39
paGe