Starter Motor; Starting Relay - Malaguti F12R L.C. 50 cc Workshop Manual

Table of Contents

Advertisement

B
Chapter

3. Starter motor

- Use a bridge cable (3) to connect the positive battery terminal (1) to the cable of the starter motor (2), as
shown in the figure.
WARNING: for the bridge, use a cable that can withstand the power draw of the starter motor otherwise
it would burn out.
- Check operation of the starter motor.
- Not compliant: replace starter motor.
F. 13

4. Starting relay

- Connect the battery to the terminals of the starting relay (4) using bridge cables (1), as follows:
- (+) cable of battery
- (-) cable of battery
CAUTION: never invert battery connections.
When connecting the battery to the relay, avoid triggering short-circuits between the
positive and negative terminals.
- Check operation of the starter motor.
- Not compliant: replace starting relay.
F. 14
18
paGe
Ignition System
2
BL
B-R
red cable.
red/white cable.
BL
3
R
R
R
R
B-R
4
1
F12R L.C. 50 cc.
1
ISSUe