GE Multilin g60 Instruction Manual page 615

Ur series generator protection system
Hide thumbs Also See for Multilin g60:
Table of Contents

Advertisement

APPENDIX B
F124
ENUMERATION: LIST OF ELEMENTS
bitmask
element
0
Phase Instantaneous Overcurrent 1
1
Phase Instantaneous Overcurrent 2
2
Phase Instantaneous Overcurrent 3
3
Phase Instantaneous Overcurrent 4
4
Phase Instantaneous Overcurrent 5
5
Phase Instantaneous Overcurrent 6
6
Phase Instantaneous Overcurrent 7
7
Phase Instantaneous Overcurrent 8
8
Phase Instantaneous Overcurrent 9
9
Phase Instantaneous Overcurrent 10
10
Phase Instantaneous Overcurrent 11
11
Phase Instantaneous Overcurrent 12
16
Phase Time Overcurrent 1
17
Phase Time Overcurrent 2
18
Phase Time Overcurrent 3
19
Phase Time Overcurrent 4
20
Phase Time Overcurrent 5
21
Phase Time Overcurrent 6
24
Phase Directional Overcurrent 1
25
Phase Directional Overcurrent 2
32
Neutral Instantaneous Overcurrent 1
33
Neutral Instantaneous Overcurrent 2
34
Neutral Instantaneous Overcurrent 3
35
Neutral Instantaneous Overcurrent 4
36
Neutral Instantaneous Overcurrent 5
37
Neutral Instantaneous Overcurrent 6
38
Neutral Instantaneous Overcurrent 7
39
Neutral Instantaneous Overcurrent 8
40
Neutral Instantaneous Overcurrent 9
41
Neutral Instantaneous Overcurrent 10
42
Neutral Instantaneous Overcurrent 11
43
Neutral Instantaneous Overcurrent 12
48
Neutral Time Overcurrent 1
49
Neutral Time Overcurrent 2
50
Neutral Time Overcurrent 3
51
Neutral Time Overcurrent 4
52
Neutral Time Overcurrent 5
53
Neutral Time Overcurrent 6
56
Neutral Directional Overcurrent 1
57
Neutral Directional Overcurrent 2
60
Negative Sequence Directional Overcurrent 1
61
Negative Sequence Directional Overcurrent 2
64
Ground Instantaneous Overcurrent 1
65
Ground Instantaneous Overcurrent 2
66
Ground Instantaneous Overcurrent 3
67
Ground Instantaneous Overcurrent 4
68
Ground Instantaneous Overcurrent 5
69
Ground Instantaneous Overcurrent 6
70
Ground Instantaneous Overcurrent 7
GE Multilin
bitmask
71
72
73
74
75
80
81
82
83
84
85
86
87
88
89
90
91
101
125
140
144
145
148
152
154
156
160
161
162
190
210
211
214
215
221
222
224
225
226
227
228
229
265
296
300
311
312
313
330
336
337
344
345
G60 Generator Protection System
B.4 MEMORY MAPPING
element
Ground Instantaneous Overcurrent 8
Ground Instantaneous Overcurrent 9
Ground Instantaneous Overcurrent 10
Ground Instantaneous Overcurrent 11
Ground Instantaneous Overcurrent 12
Ground Time Overcurrent 1
Ground Time Overcurrent 2
Ground Time Overcurrent 3
Ground Time Overcurrent 4
Ground Time Overcurrent 5
Ground Time Overcurrent 6
Restricted Ground Fault 1
Restricted Ground Fault 2
Restricted Ground Fault 3
Restricted Ground Fault 4
Restricted Ground Fault 5
Restricted Ground Fault 6
Opposite Phase Rotation
Generator Unbalance
Auxiliary Undervoltage 1
Phase Undervoltage 1
Phase Undervoltage 2
Auxiliary Overvoltage 1
Phase Overvoltage 1
Compensated Overvoltage 1
Neutral Overvoltage 1
Phase Distance Zone 1
Phase Distance Zone 2
Phase Distance Zone 3
Power Swing Detect
Volt per Hertz 1
Volt per Hertz 2
Sensitive Directional Power 1
Sensitive Directional Power 2
100% Stator Ground
Split Phase Protection
SRC1 VT Fuse Failure
SRC2 VT Fuse Failure
SRC3 VT Fuse Failure
SRC4 VT Fuse Failure
SRC5 VT Fuse Failure
SRC6 VT Fuse Failure
Stator Differential
Accidental Energization
Loss Of Excitation
Phasor measurement unit one-shot
Synchrocheck 1
Synchrocheck 2
Third harmonic neutral undervoltage
Setting Group
Reset
Overfrequency 1
Overfrequency 2
B
B-69