3.1 DESCRIPTION
The 4.0x release of the G60 relay includes new hardware modules.The new CPU modules are specified with codes
9E and higher. The new CT/VT modules are specified with the codes 8F and higher.
NOTE
The new CT/VT modules can only be used with new CPUs; similarly, old CT/VT modules can only be used with old
CPUs. To prevent hardware mismatches, the new modules have blue labels and a warning sticker stating "Attn.:
Ensure CPU and DSP module label colors are the same!". In the event that there is a mismatch between the
CPU and CT/VT module, the relay will not function and a
played.
All other input and output modules are compatible with the new hardware. Firmware versions 4.0x and higher are
only compatible with the new hardware modules. Previous versions of the firmware (3.4x and earlier) are only com-
patible with the older hardware modules.
3
X
W
V
Tx1
Rx1
Tx1
Tx2
Rx2
Tx2
Optional
Optional
Ethernet
direct
switch
input/output
module
Do not touch any rear terminals while the relay is energized!
WARNING
The relay follows a convention with respect to terminal number assignments which are three characters long assigned in
order by module slot position, row number, and column letter. Two-slot wide modules take their slot designation from the
first slot position (nearest to CPU module) which is indicated by an arrow marker on the terminal block. See the following
figure for an example of rear terminal assignments.
3-8
G60
Generator Management Relay
GE Multilin
Technical Support:
Tel: (905) 294-6222
http://www.GEIndustrial.com/Multilin
Fax: (905) 201-2098
U
T
S
R
P
N
c
b
a
c
b
Optional
Optional
contact
CT/VT or
input/output
contact
module
input/output
module
Figure 3–10: REAR TERMINAL VIEW
G60 Generator Protection System
or
DSP ERROR
HARDWARE MISMATCH
G60D00HCHF8AH6AM6BP8BX7A
Model:
RATINGS:
000
Mods:
Control Power:
88-300V DC @ 35W / 77-265V AC @ 35VA
ZZZZZZ
Wiring Diagram:
Contact Inputs:
300V DC Max 10mA
D
Inst. Manual:
Contact Outputs:
Standard Pilot Duty / 250V AC 7.5A
MAZB98000029
Serial Number:
360V A Resistive / 125V DC Break
D
Firmware:
4A @ L/R = 40mS / 300W
1998/01/05
Mfg. Date:
Made in
®
Canada
®
-
M
A
A
B
9
7
0
M
L
K
J
H
G
a
c
b
a
c
b
Optional
CT/VT
contact
module
input/output
module
3 HARDWARE
error will be dis-

3.1.3 REAR TERMINAL LAYOUT

0
0
0
9
9
-
F
D
B
a
b
a
b
a
1
1
1
2
2
2
3
3
Tx1
3
4
4
4
5
Rx1
CH1
6
Tx
Rx
CH2
7
IN
Tx2
8
OUT
Rx2
CPU module
Power
(Ethernet not
supply
available when
module
ordered with
Ethernet switch)
830720A3.CDR
GE Multilin
1
2
3
4
5
6
7
8

Advertisement

Table of Contents
loading

Table of Contents