GE Multilin g60 Instruction Manual page 575

Ur series generator protection system
Hide thumbs Also See for Multilin g60:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 22 of 59)
ADDR
REGISTER NAME
5F54
Frequency Out-Of-Band Accumulator 2 Time Limit
5F55
Frequency Out-Of-Band Accumulator 3 Time Limit
5F56
Frequency Out-Of-Band Accumulator 4 Time Limit
5F57
Frequency Out-Of-Band Accumulator 5 Time Limit
5F58
Frequency Out-Of-Band Accumulator 6 Time Limit
5F59
Frequency Out-Of-Band Accumulator 7 Time Limit
5F5A
Frequency Out-Of-Band Accumulator 1 Time Preset
5F5B
Frequency Out-Of-Band Accumulator 2 Time Preset
5F5C
Frequency Out-Of-Band Accumulator 3 Time Preset
5F5D
Frequency Out-Of-Band Accumulator 4 Time Preset
5F5E
Frequency Out-Of-Band Accumulator 5 Time Preset
5F5F
Frequency Out-Of-Band Accumulator 6 Time Preset
5F60
Frequency Out-Of-Band Accumulator 7 Time Preset
5F61
Frequency Out-Of-Band Accumulator 1 Upper Frequency
5F62
Frequency Out-Of-Band Accumulator 2 Upper Frequency
5F63
Frequency Out-Of-Band Accumulator 3 Upper Frequency
5F64
Frequency Out-Of-Band Accumulator 4 Upper Frequency
5F65
Frequency Out-Of-Band Accumulator 5 Upper Frequency
5F66
Frequency Out-Of-Band Accumulator 6 Upper Frequency
5F67
Frequency Out-Of-Band Accumulator 7 Upper Frequency
Setting Groups (Read/Write Setting)
5F80
Setting Group for Modbus Comms (0 means group 1)
5F81
Setting Groups Block
5F82
FlexLogic to Activate Groups 2 through 6 (5 items)
5F89
Setting Group Function
5F8A
Setting Group Events
Setting Groups (Read Only)
5F8B
Current Setting Group
Setting Group Names (Read/Write Setting)
5F8C
Setting Group 1 Name
5F94
Setting Group 2 Name
5F9C
Setting Group 3 Name
5FA4
Setting Group 4 Name
5FAC
Setting Group 5 Name
5FB4
Setting Group 6 Name
Stator Differential (Read/Write Grouped Setting)
6470
Stator Differential Function
6471
Stator Differential Pickup
6472
Stator Differential Slope 1
6473
Stator Differential Slope 2
6474
Stator Differential Break 1
6475
Stator Differential Break 2
6476
Stator Differential Block
6477
Stator Differential Targets
6478
Stator Differential Events
6479
Stator Differential Line End Source
647A
Stator Differential Neutral End Source
Negative Sequence Overvoltage (Read/Write Grouped Setting)
64A0
Negative Sequence Overvoltage Function
64A1
Negative Sequence Overvoltage Source
64A2
Negative Sequence Overvoltage Pickup
64A3
Negative Sequence Overvoltage Pickup Delay
64A4
Negative Sequence Overvoltage Reset Delay
64A5
Negative Sequence Overvoltage Block
GE Multilin
RANGE
1 to 65535
1 to 65535
1 to 65535
1 to 65535
1 to 65535
1 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
20.00 to 70.00
20.00 to 70.00
20.00 to 70.00
20.00 to 70.00
20.00 to 70.00
20.00 to 70.00
20.00 to 70.00
0 to 5
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 5
---
---
---
---
---
---
0 to 1
0.05 to 1
1 to 100
1 to 100
1 to 1.5
1.5 to 30
0 to 65535
0 to 2
0 to 1
0 to 5
0 to 5
0 to 1
0 to 5
0 to 1.25
0 to 600
0 to 600
0 to 65535
G60 Generator Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
s
1
F001
s
1
F001
s
1
F001
s
1
F001
s
1
F001
s
1
F001
s
1
F001
s
1
F001
s
1
F001
s
1
F001
s
1
F001
s
1
F001
s
1
F001
Hz
0.01
F001
Hz
0.01
F001
Hz
0.01
F001
Hz
0.01
F001
Hz
0.01
F001
Hz
0.01
F001
Hz
0.01
F001
---
1
F001
---
1
F300
---
1
F300
---
1
F102
---
1
F102
---
1
F001
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
1
F102
pu
0.001
F001
%
1
F001
%
1
F001
pu
0.01
F001
pu
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F167
---
1
F167
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
DEFAULT
200
200
200
200
200
B
200
0
0
0
0
0
0
0
6000
6000
6000
6000
6000
6000
6000
0
0
0
0 (Disabled)
0 (Disabled)
0
(none)
(none)
(none)
(none)
(none)
(none)
0 (Disabled)
100
10
80
115
800
0
0 (Self-reset)
0 (Disabled)
0 (SRC 1)
0 (SRC 1)
0 (Disabled)
0 (SRC 1)
300
50
50
0
B-29