GE Multilin g60 Instruction Manual page 586

Ur series generator protection system
Hide thumbs Also See for Multilin g60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 33 of 59)
ADDR
REGISTER NAME
7F35
Auxiliary Overvoltage 1 Block
7F36
Auxiliary Overvoltage 1 Target
7F37
Auxiliary Overvoltage 1 Events
7F38
Reserved (8 items)
7F40
...Repeated for Auxiliary Overvoltage 2
B
7F50
...Repeated for Auxiliary Overvoltage 3
Auxiliary Undervoltage (Read/Write Grouped Setting) (3 modules)
7F60
Auxiliary Undervoltage 1 Function
7F61
Auxiliary Undervoltage 1 Signal Source
7F62
Auxiliary Undervoltage 1 Pickup
7F63
Auxiliary Undervoltage 1 Delay
7F64
Auxiliary Undervoltage 1 Curve
7F65
Auxiliary Undervoltage 1 Minimum Voltage
7F66
Auxiliary Undervoltage 1 Block
7F67
Auxiliary Undervoltage 1 Target
7F68
Auxiliary Undervoltage 1 Events
7F69
Reserved (7 items)
7F70
...Repeated for Auxiliary Undervoltage 2
7F80
...Repeated for Auxiliary Undervoltage 3
Frequency (Read Only)
8000
Tracking Frequency
EGD Fast Production Status (Read Only)
83E0
EGD Fast Producer Exchange 1 Signature
83E1
EGD Fast Producer Exchange 1 Configuration Time
83E3
EGD Fast Producer Exchange 1 Size
EGD Slow Production Status (Read Only) (2 modules)
83F0
EGD Slow Producer Exchange 1 Signature
83F1
EGD Slow Producer Exchange 1 Configuration Time
83F3
EGD Slow Producer Exchange 1 Size
83F4
...Repeated for module number 2
EGD Fast Production (Read/Write Setting)
8400
EGD Fast Producer Exchange 1 Function
8401
EGD Fast Producer Exchange 1 Destination
8403
EGD Fast Producer Exchange 1 Data Rate
8404
EGD Fast Producer Exchange 1 Data Item 1 (20 items)
8418
Reserved (80 items)
EGD Slow Production (Read/Write Setting) (2 modules)
8500
EGD Slow Producer Exchange 1 Function
8501
EGD Fast Producer Exchange 1 Destination
8503
EGD Slow Producer Exchange 1 Data Rate
8504
EGD Slow Producer Exchange 1 Data Item 1 (50 items)
8536
Reserved (50 items)
8568
...Repeated for EGD Exchange 2
Remote RTD inputs (Read/Write Grouped Setting) (12 modules)
86D0
Remote RTD 1 Function
86D1
Remote RTD 1 ID
86D7
Remote RTD 1 Type
86D8
Remote RTD 1 Application
86D9
Remote RTD 1 Alarm Temperature
86DA
Remote RTD 1 Alarm Pickup Delay
86DB
Remote RTD 1 Trip Temperature
86DC
Remote RTD 1 Trip Pickup Delay
86DD
Remote RTD 1 Trip Reset Delay
86DE
Remote RTD 1 Trip Voting
B-40
RANGE
0 to 65535
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 5
0 to 3
0 to 600
0 to 1
0 to 3
0 to 65535
0 to 2
0 to 1
0 to 65535
---
0 to 65535
0 to 4294967295
0 to 65535
0 to 65535
0 to 4294967295
0 to 65535
0 to 1
0 to 4294967295
50 to 1000
0 to 65535
---
0 to 1
0 to 4294967295
500 to 1000
0 to 65535
---
0 to 1
---
0 to 3
0 to 5
1 to 200
5 to 600
1 to 200
5 to 600
5 to 600
0 to 13
G60 Generator Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
---
1
F111
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
Hz
---
F001
---
1
F001
---
---
F003
---
1
F001
---
1
F001
---
---
F003
---
1
F001
---
1
F102
---
1
F003
ms
50
F001
---
1
F001
---
---
F001
---
1
F102
---
1
F003
ms
50
F001
---
1
F001
---
---
F001
---
1
F102
---
---
F205
---
1
F174
0 (100 ohm Platinum)
---
1
F550
°C
1
F001
seconds
5
F001
°C
1
F001
seconds
5
F001
seconds
5
F001
---
1
F603
DEFAULT
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
700
100
0 (Definite Time)
100
0
0 (Self-reset)
0 (Disabled)
0
0
0
0
0
0
0
0
0 (Disabled)
0
1000
0
0
0 (Disabled)
0
1000
0
0
0 (Disabled)
"RRTD 1"
0 (None)
130
5
130
5
5
0 (None)
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents