A.1 PARAMETER LISTS
Table A–1: FLEXANALOG DATA ITEMS (Sheet 14 of 23)
A
ADDRESS
FLEXANALOG NAME
9548
PMU 1 V1 Mag
9550
PMU 1 V1 Angle
9551
PMU 1 V2 Mag
9553
PMU 1 V2 Angle
9554
PMU 1 V0 Mag
9556
PMU 1 V0 Angle
9557
PMU 1 Ia Mag
9559
PMU 1 Ia Angle
9560
PMU 1 Ib Mag
9562
PMU 1 Ib Angle
9563
PMU 1 Ic Mag
9565
PMU 1 Ic Angle
9566
PMU 1 Ig Mag
9568
PMU 1 Ig Angle
9569
PMU 1 I1 Mag
9571
PMU 1 I1 Angle
9572
PMU 1 I2 Mag
9574
PMU 1 I2 Angle
9575
PMU 1 I0 Mag
9577
PMU 1 I0 Angle
9578
PMU 1 Freq
9580
PMU 1 df dt
9581
PMU 1 Conf Ch
10240
SRC 1 Ia THD
10241
SRC 1 Ia Harm[0]
10242
SRC 1 Ia Harm[1]
10243
SRC 1 Ia Harm[2]
10244
SRC 1 Ia Harm[3]
10245
SRC 1 Ia Harm[4]
10246
SRC 1 Ia Harm[5]
10247
SRC 1 Ia Harm[6]
10248
SRC 1 Ia Harm[7]
10249
SRC 1 Ia Harm[8]
10250
SRC 1 Ia Harm[9]
10251
SRC 1 Ia Harm[10]
10252
SRC 1 Ia Harm[11]
10253
SRC 1 Ia Harm[12]
10254
SRC 1 Ia Harm[13]
10255
SRC 1 Ia Harm[14]
10256
SRC 1 Ia Harm[15]
10257
SRC 1 Ia Harm[16]
10258
SRC 1 Ia Harm[17]
10259
SRC 1 Ia Harm[18]
10260
SRC 1 Ia Harm[19]
10261
SRC 1 Ia Harm[20]
10262
SRC 1 Ia Harm[21]
10263
SRC 1 Ia Harm[22]
A-14
UNITS
DESCRIPTION
Volts
Phasor measurement unit 1 positive-sequence voltage magnitude
Degrees
Phasor measurement unit 1 positive-sequence voltage angle
Volts
Phasor measurement unit 1 negative-sequence voltage magnitude
Degrees
Phasor measurement unit 1 negative-sequence voltage angle
Volts
Phasor measurement unit 1 zero-sequence voltage magnitude
Degrees
Phasor measurement unit 1 zero-sequence voltage angle
Amps
Phasor measurement unit 1 phase A current magnitude
Degrees
Phasor measurement unit 1 phase A current angle
Amps
Phasor measurement unit 1 phase B current magnitude
Degrees
Phasor measurement unit 1 phase B current angle
Amps
Phasor measurement unit 1 phase C current magnitude
Degrees
Phasor measurement unit 1 phase C current angle
Amps
Phasor measurement unit 1 ground current magnitude
Degrees
Phasor measurement unit 1 ground current angle
Amps
Phasor measurement unit 1 positive-sequence current magnitude
Degrees
Phasor measurement unit 1 positive-sequence current angle
Amps
Phasor measurement unit 1 negative-sequence current magnitude
Degrees
Phasor measurement unit 1 negative-sequence current angle
Amps
Phasor measurement unit 1 zero-sequence current magnitude
Degrees
Phasor measurement unit 1 zero-sequence current angle
Hz
Phasor measurement unit 1 frequency
Hz/s
Phasor measurement unit 1 rate of change of frequency
---
Phasor measurement unit 1 configuration change counter
---
Source 1 phase A current total harmonic distortion
Amps
Source 1 phase A current second harmonic
Amps
Source 1 phase A current third harmonic
Amps
Source 1 phase A current fourth harmonic
Amps
Source 1 phase A current fifth harmonic
Amps
Source 1 phase A current sixth harmonic
Amps
Source 1 phase A current seventh harmonic
Amps
Source 1 phase A current eighth harmonic
Amps
Source 1 phase A current ninth harmonic
Amps
Source 1 phase A current tenth harmonic
Amps
Source 1 phase A current eleventh harmonic
Amps
Source 1 phase A current twelfth harmonic
Amps
Source 1 phase A current thirteenth harmonic
Amps
Source 1 phase A current fourteenth harmonic
Amps
Source 1 phase A current fifteenth harmonic
Amps
Source 1 phase A current sixteenth harmonic
Amps
Source 1 phase A current seventeenth harmonic
Amps
Source 1 phase A current eighteenth harmonic
Amps
Source 1 phase A current nineteenth harmonic
Amps
Source 1 phase A current twentieth harmonic
Amps
Source 1 phase A current twenty-first harmonic
Amps
Source 1 phase A current twenty-second harmonic
Amps
Source 1 phase A current twenty-third harmonic
Amps
Source 1 phase A current twenty-fourth harmonic
G60 Generator Protection System