06.90
6131
Syncro
error MC5 pgoram
Synchronization
pattern
for
STEP
5 program blocks no longer correct
PLC-STOP
PLC GENERAL RESET, reload PLC program
Cause:
Effect:
Remedy:
6132
Synchro
error
MC5 data
Cause:
Synchronization
pattern
for
STEP
5 data blocks no longer correct
PLC-STOP
PLC GENERAL
RESET, reload
PLC program
Effect:
Remedy:
6133
Illegal block basic
program
Effect:
Remedy:
PLC-STOP
Replace
system
software
6134
Illegal
block MC5
program
PLC-STOP
PLC GENERAL
RESET, reload PLC program
Effect:
Remedy:
6135
Illegal block MC5 data
PLC-STOP
PLC GENERAL
RESET, reload PLC program
Effect:
Remedy:
6136
Summing error MC5 block
PLC-STOP
PLC GENERAL RESET, reload PLC program
Effect:
Remedy:
6137
Summing error basic program
PLC-STOP
Replace
system
software
Effect:
Remedy:
8-35
®