8 Monitoring
8.3.3 List of alarms
06.90
35
SIEMENS reader error (RS 232C)
Error message
output
from
SIEMENS
tape
reader
-
Only when parameters for
SIEMENS reader
have been set
-
Data transfer interrupted
-
Last block
not
stored
-
Restart data transfer
-
If error reoccurs: replace
SIEMENS
reader.
Cause:
Scan:
Effect:
Remedy:
104*
DAC limitation
Scan:
Effect:
Cyclic
No direct effect. Absorbed by the following
error
alarm
156*
The
DAC
setpoint entered is higher
than in MD
268* (max.
DAC
setpoint)
It is
not possible to
increase the setpoint any further!
Traverse more slowly
Check the actual values
(encoder)
Check MD
268*
Check the drive
actuator
Check MD 364* and MD
368*
Explanation:
Remedy:
108*
Actual part position overrun
Scan:
Effect:
At each axis
movement (also
follow-up mode)
Interlocking of NC START
Setpoint relay drop (setpoint
0)
Removal of NC READY 2.
Servo enable
is
removed
in
MD
1
56 after delay has
elapsed
(servo
enable
relays drop
out)
NC/PLC
interface is
put
into the inactive state
Follow-up mode
Actual value of the machine is lost
(incorrect position).
The actual
part
value is multiplied by the control.
With rapid
traverse
of the axis the register overflows in the case of the fault. The
reference
point is lost.
Reduce maximum
speed
Check MD
for variable incremental weighting
(MD* 364 and MD
368*)
Explanation: