Siemens SINUMERIK 805 Operating Instructions Manual page 224

Table of Contents

Advertisement

8 Monitoring
8.3.3 List of alarms
06.90
6103
Transfer
to
missing
DB
L DW
and/or
T DW without previously
calling
a data block
(A DB)
PLC-STOP
Check PLC
program,
U-STACK
Cause:
Effect:
Remedy:
6104
Substitution error
Error whilst substituting a PLC
command
PLC-STOP
Check PLC program
(U-STACK)
Cause:
Effect:
Remedy:
6105
Missing
MC5 block
Cause:
Calling
a block which is
not
in the control
(OB, PB, SB, FB)
PLC-STOP
e.g. OB
2 not
available
Enter missing block.
Effect:
Explanation:
Remedy:
6106
Missing data block
Cause:
Effect:
Remedy:
Calling a data block which is
not
in the control
PLC-STOP
Enter missing data block
6107
Invalid segment
LIR/TIR
LIR:
segment
nos. 0-A valid
TIR:
segment
nos. 0-6 valid
PLC-STOP
See LIR/TIR Programming Instructions
Correct program
Cause:
Effect:
Explanation:
Remedy:
6108
Invalid segment TNB/TNW
segment nos. 0 to
A valid
segment
nos.
0
to
6 valid
Source:
Destination:
PLC-STOP
See TNB/TNW Programming Instructions
Correct program
Cause:
Effect:
Explanation:
Remedy:
8-31
©
Siemens AG
1990 All Rights
Reserved
6ZB5410-0EE02
SINUMERIK
805,
SW2
(BA)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents