8 Monitoring
8.3.3 List of alarms
06.90
16
Parity
error
RS 232 C
-
RS 232
C transmission interrupted
-
Last block
declared
invalid
Alarm
can
only occur if parity is selected.
The
character commenced has
incorrect
parity.
The
alarm has nothing to do with character parity errors
RS
232
C
in
ISO
or
EIA punched
tapes (alarm 23)
-
Check RS
232
C
parameters
-
Check external device
Effect:
Explanation:
Remedy:
17
Overflow error RS232 C
Effect:
RS232 C transfer interrupted
-
Last block
declared as
invalid
The
external
device
has
sent
a new character although the CNC has
not
yet processed
the old
one.
-
Check RS 232 C interface
parameters
-
Test external device
Explanation:
Remedy:
18
Frame error RS 232 C
RS 232 C transfer
is interrupted
Last block declared invalid
Number of
stop
bits is incorrect
Incorrect baud
rate
Number of data bits is
incorrect
Check RS 232 C interface
parameters
Test external device
Number of data bits:
7
data bits
+
1
parity bit
(set
external
device)
Effect:
Explanation:
Remedy:
19
I/O device not ready RS232 C
No files are
read in
The DSR signal from the external device is LOW
-
Start external
device
-
Do
not
use DSR
Effect:
Explanation:
Remedy: