06.90
8 Monitoring
8.3.3 List of alarms
31
No
further
part
program input possible
(RS 232 C)
Cause:
The maximum number of programs stipulated by machine data has been
reached.
-
Delete old programs and
reorganize
memory
-
Modify MD 8 and reformat part program memory
Order:
a.
'ÿINITIALIZATION''
mode
b. "Format
user
data" softkey
c. "Format
part
program
memory" softkey
Old programs are also deleted!
Remedy:
32
Data format error (RS 232 C)
Cause:
The permissible number of decades after an address is
not correct
The decimal point
occurs
in the wrong place
Part programs and subroutines are
not
correctly defined or
concluded
(check heading!)
NC expecting an
" =
" character,
which
is however
not
correctly
defined
in the
EIA code.
Data transfer interrupted. Last block
is
not
stored
Check
the program
to
be read in
Effect:
Remedy:
33
Programs differ (RS 232 C)
Cause:
Read-in and stored program
not
identical with program with same
number
No data is stored
Delete old program or
rename old
program
If a new program is read in which has the same program number as one
already
stored,
both programs
are
compared. If the programs
are
different, an alarm is given.
Effect:
Remedy:
Explanation:
34
Operator error (RS 232 C)
Cause:
Data transfer in NC has started and the
PLC
gives
second signal
No data is read in
Stop data input and
restart
Effect:
Remedy: