Siemens SINUMERIK 805 Operating Instructions Manual page 216

Table of Contents

Advertisement

8 Monitoring
8.3.3 List of alarms
06.90
2152
Spindle speed
too
high
Only when MD 520* bit 2 is
set (encoder available)
The spindle speed is higher than fixed in
the machine
data
-
Program lower S value
MD
403*
-
410'
(max.
spindle speed for the first
to eighth
gear
stage)
-
MD
445* (tolerance band for max. spindle speed)
-
MD
451* (max. spindle speed)
-
Gear
stage correctly selected by
PLC?
G92 S...
if v
constant
is incorrectly programmed
Scan:
Explanation:
Remedy:
2153
Control loop error (spindle)
Scan:
Effect:
Cyclic
-
Interlocking
of
NC START
-
Drop
out
of setpoint relay
Setpoint 0
-
Removal
of
NC READY 2
-
Servo enable of spindles is removed in MD
4470 after delay has
elapsed
As for alarm
132*
As for alarm
132*
Explanation:
Remedy:
2154
Measuring
system
dirty (spindle)
Scan:
Explanation:
Cyclic
In the case of measuring
systems
with a contamination signal, a fault is
transmitted
to the
NC
Interlocking of NC START
Check the measuring
system
Effect:
Remedy:
2155
Option
not
available
Scan:
Effect:
Explanation:
On traversing
in
AUTOMATIC/M DA
mode
Interlocking of NC START
"M19 S..." is programmed in the
part
program although this function is
not
available
-
Correct program
-
Retrofit M
1
9
Remedy:
8-23
©
Siemens AG 1990 Alt Rights Reserved
6ZB5
4 1
0-OEE02
SINUMERIK
805,
SW2
(BA)

Hide quick links: