MODEL 1057
Fault and Warning banner:
If the analyzer detects a problem with itself or the sensor the word Fault or Warning will appear at the bottom of
the display. A fault requires immediate attention. A warning indicates a problematic condition or an impending fail-
ure. For troubleshooting assitance, press Diag.
Formatting the Main Display
The main display screen can be programmed to show primary process variables, secondary process variables and
diagnostics.
1.
Press MENU
2.
Scroll down to Display. Press ENTER.
3.
Main Format will be highlighted. Press ENTER.
4.
The sensor 1 process value will be highlighted in reverse video. Press the selection keys to navigate down
to the screen sections that you wish to program. Press ENTER.
5.
Choose the desired display parameter or diagnostic for each of the four display sections in the lower screen.
6.
Continue to navigate and program all desired screen sections.
return to the main display.
For single sensor configurations, the default display shows the live process measurement in the upper display area
and temperature in the center display area. The user can elect to disable the display of temperature in the center
display area using the Main Format function. See Fig. 4-1 to guide you through programming the main display to
select process parameters and diagnostics of your choice.
For dual sensor configurations, the default display shows Sensor 1 live process measurement in the display area
1 and Sensor 2 live process measurement temperature in the display area 2. See Fig. 4-1 to guide you through
programming the main display to select process parameters and diagnostics of your choice.

4.4 MENU SYSTEM

Model 1057 uses a scroll and select menu system.
Pressing the MENU key at any time opens the top-level
menu including Calibrate, Hold, Program and Display
functions.
To find a menu item, scroll with the up and down keys
until the item is highlighted.
select menu items until the desired function is chosen.
To select the item, press ENTER. To return to a previ-
ous menu level or to enable the main live display,
press the EXIT key repeatedly. To return immediately
to the main display from any menu level, simply press
MENU then EXIT.
The selection keys have the following functions:
The Up key (above ENTER) increments numerical values, moves the decimal place one place to the right,
or selects units of measurement.
The Down key (below ENTER) decrements numerical values, moves the decimal place one place to the
left, or selects units of measurement
The Left key (left of ENTER) moves the cursor to the left.
The Right key (right of ENTER) moves the cursor to the right.
To access desired menu functions, use the "Quick Reference" Figure B. During all menu displays (except main
display format and Quick Start), the live process measurements and secondary measurement values are
displayed in the top two lines of the Upper display area. This conveniently allows display of the live values during
important calibration and programming operations.
Menu screens will time out after two minutes and return to the main live display.
Continue to scroll and
DISPLAY AND OPERATION
Press MENU and EXIT. The screen will