How To Turn On the Appliance

Prerequisites
1. Turn on the exhaust hood.
2. Make sure that the water supply to the appliance is turned on.
3. Make sure that the electrical power supply to the appliance
is turned on.
4. For gas appliances, make sure the gas supply valve is in the
open position.
Steps
1. Press the ON/OFF button
The ON/OFF indicator glows green and the loading screen
displays while the controller software loads. When the software
is 100% loaded, the home screen
note: If the appliance has a steam generator, the steam
generator fills with water and the appliance heats the water to
an initial temperature of 188°F (77°C).

How To Start a Manual Calibration

1. Make sure the appliance is off.
2. Press and hold the ON/OFF button
The ON/OFF indicator glows red and the calibration prompt
displays.
The prompt moves from the center to all four corners of
the screen. This sequence repeats three (3) times. Then the
calibration screen
displays.
4
note: The first time the appliance is turned on, or if the
appliance loses power during startup, the touchscreen
calibration prompt
displays at the end of the next startup.
3
note: Touch the check mark icon
immediately. Touch the cancel icon
calibration.

How To Calibrate the Touchscreen

+
1. Touch the target icon (
icon appears in all four corners, then the center of the screen.
note: If the controller software has not been updated to
the current version (11/16 update), the calibration stops
when this step is complete. download the current controller
software from the Alto-Shaam website and install it.
2. The verification screen
. The icons change to green boxes when they are touched.
note: The calibration screen and verification screen both
display a 30-second countdown. If you do not touch all five
icons before the countdown is complete, the controller stops
the calibration. If you do not see the countdown, download
the current controller software from the Alto-Shaam website
and install it.

How To Turn Off the Appliance

1. Press and hold the ON/OFF button
seconds.
MN-35947
CT PROformance™ Start-Up Procedures
.
displays.
2
for eight (8) seconds.
to start the calibration
to cancel the
) each time it appears on screen. The
displays. Touch all five target icons
5
for five to ten (5-10)
Rev 12
11/16
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
Before starting the appliance, make certain you do
not detect the odor of gas.
If you smell gas:
• Shut off the gas supply immediately.
• Do not attempt to light any appliance.
• Do not touch any electrical elements.
• Extinguish any open flame.
• Evacuate the area.
• Use a telephone outside the property and
immediately contact your gas supplier.
• If unable to contact your as supplier, contact the
fire department.
1
C A u T I O N
Accumulations on the main burners of gas
appliances can result in firing out of normal
sequence. This delayed ignition creates an
alarmingly loud sound. If your appliance makes
an especially loud noise when starting up, shut
down the appliance and call a qualified and
trained service technician.