C O m B I H O O D p L u S ™ V E N T L E S S H O O D O p T I O N
The CombiHood PLUS option is factory installed directly
on the top of the Alto-Shaam Combitherm CTP or CTC
series oven.
• Using EPA method 202 testing, grease laden vapors
emitted by the Combi Ventless hood are 0.58 mg/m
far less than U.L.'s established standard of 5 mg/m
• A high-powered fan captures all steam and fumes from
the oven cavity into the hood intake and out the back
surface exhaust vent, trapping grease as the air moves
through the lter system.
• As fumes and vapors are circulated through the hood,
condensed steam drains from a drain at the rear of the
hood.
• An activated charcoal lter cleans the air before
venting it out the top of the hood.
• CombiHood PLUS™ performance is "smart"; engaging
the fan during the last minute of the cook mode which
provides quiet operation and consumes less power.
1
CombiHood Plus Washable Grease Filter with metal housing
(5017362)
Washing frequency should be based on oven usage with a
maximum of two weeks between cleaning if the oven is used
for non-grease laden products or steam applications only.
Grease laden products require cleaning frequency of at least
once a week.
Remove the grease lter by pulling it straight out of
the housing. Place the lter in the dishwasher or wash
separately by placing in hot, soapy water until all grease and
particles have been removed. Rinse thoroughly. Allow the
lter to air dry before reinstalling.
The air ow arrow on the lter casing should point toward
the hood fan when the lter is reinstalled.
56
MN-35947
3
.
3
Quarter Turn Release
(access to filters)
Rev 12
11/16
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
FRONT OF HOOD
ALIGNS WITH FRONT
OF COMBI DOOR
1
2
Quarter Turn Release
(access to filters)
2
CombiHood Plus Charcoal Filter with paper housing, Class II
(FI-25866)
CombiHood Plus Charcoal Filter with metal housing, Class I
required for New York City and Los Angeles (FI-36620)
The charcoal lter should be inspected once a month for
contaminants. Replacement must be made at a minimum of
three month intervals — more o en if heavy contaminants
are visible or if the lter no longer controls odors.
To remove the lter, pull and slide out while holding the
bottom housing. When replacing the lter, make certain
the air ow arrow(s) point toward the hood fan, and that the
lter is replaced in the three-sided metal frame provided
with the hood.
NOTICE: A pressure switch is used to detect when the air ow
through the charcoal lter is reduced by 25% - indicating
a possible blockage. This will generate an E101 error
message on the oven control display. The lters will need
to cleaned or replaced.
If the lters are not seated properly, an error code E102
will appear on the oven control display at the end of a
cooking cycle.
Condensate Drain
A condensate drain line to the
oor drain must be installed.
The 1/2" barbed connection is
found at the back of the hood.
The drain line must always be a
positive gradient away from the
Combitherm oven.
Test the drain for proper drainage
and signs of leaking on a monthly
basis.