W AT E R D R A I N A g E – f O R S T A C K E D O V E N
A union is required. Install a 1-1/2-inch (41mm) diameter connection, drain line and clamp into place.
The drain line must always be a positive gradient away from the Combitherm oven. An end of drain run
air gap may be required by local code. Vertical air vent required.
NOTICE: In the U.S.A., this equipment is to be installed to comply with the Basic Plumbing Code of the
Building Officials and Code Administrators International, Inc. [BOCA], and the Food Service
Sanitation Manual of the Food & drug Administration [FdA].
Installation kits have a maximum run
54
MN-35947
WARNING:
To prevent SERIOUS INJURY or PROPERTY DAMAGE
from slippery floor conditions, check drain is connected
properly and not blocked.
length of 4-1/2' (1372mm).
1-1/2" (40mm) diameter pipe
To Drain - Floor Sink
with Positive Descending Slope
Rev 12
11/16
One suggested method of drain installation.
Drain materials must
withstand temperatures
up to 200°F (93°C).
If a drain run exceeds 6' (1829mm)
to the floor sink, an air gap is
strongly recommended.
When stacking ovens, run
independent drains.
Use only glue designed for CPVC.
Drain
Connection
1-1/2" (40mm) diameter
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
Drain vent pipes must
be above oven exhaust
vent opening!
Exhaust vent opening
1-1/2" (40mm) CPVC
Tee Fitting Drain Connection
45 Degree Elbow
1-1/2" (40mm) diameter
CPVC Tee Fitting
Drain Connection
45 Degree Elbow